Lowrance electronic LMF-200 Pop-up Thresholds, RPM Threshold set up, Engine Trim Threshold set up

Models: LMF-200

1 72
Download 72 pages 48.35 Kb
Page 23
Image 23

4.After entering the desired stay time, press MENU. You will be taken to the main display.

Pop-up Thresholds

Once you have chosen the pages you want to monitor, you will need to set a threshold for each page. A pop up will not appear for a page unless a threshold has been chosen. When a threshold is exceeded, the pop-up window will appear. If, for example, you set the RPM threshold to 500 RPM and choose a 10-second Stay on Time, the RPM page will pop up if there is a change in RPM that exceeds 500 RPM — like decreasing RPM from 2000 RPM to 1300 RPM. The pop up will expire 10 seconds after the RPM data stops changing. The gauge will revert to the page it was showing before the threshold was exceeded.

RPM Threshold set up:

Make sure RPM has been selected on the Pop-up Pages menu before setting a RPM threshold. If it has not been selected on the Pop-up Page menu, a RPM pop-up will not appear, regardless of the threshold.

1.Press MENU, use the UP and DOWN keys to select PAGES and press MENU. Highlight SET POP-UPand press MENU.

2.The Set Pop-up menu will appear with three options: Pages, Threshold and Stay Time. Select THRESHOLD and press MENU.

3.To set the threshold for RPM, highlight RPM and press MENU.

4.Use the UP and DOWN keys to select a RPM level between 50 and 3000 RPM. Press MENU and you will be taken back to the main display.

Engine Trim Threshold set up:

Make sure Engine Trim has been selected on the Pop-up Pages menu before setting an Engine Trim threshold. If it has not been selected on the Pop-up Page menu, an Engine Trim pop-up will not appear, regardless of the threshold.

1.Press MENU, use the UP and DOWN keys to select PAGES and press MENU. Highlight SET POP-UPand press MENU.

2.The Set Pop-up menu will appear with three options: Pages, Threshold and Stay Time. Select THRESHOLD and press MENU.

3.Select ENGINE TRIM from the Threshold menu and press MENU.

4.Use the UP and DOWN keys to choose a threshold between 3 and 50 percent. Press MENU and you will be taken back to the main display.

Trim Tabs Threshold set up:

Make sure Trim Tabs have been selected on the Pop-up Pages menu before setting a threshold. If Trim Tabs are not selected on the Pop-up Page menu, a Trim Tab pop-up will not appear, regardless of the threshold.

17