NOTE:

If the difference between the LMF-200 fuel used figure and the amount of fuel you actually added to the tank is less than 3 percent the EP-10 Fuel Flow does not need to be calibrated.

7.To recalibrate the unit, fill up the fuel tank connected to the fuel flow you want to calibrate.

8.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

9.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. The Select Tank menu will open with three options: Port, Cen (Center) and Stbd (Starboard). Select the tank you refilled and press MENU.

10.The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select YES and press MENU.

11.The Filled Quantity window will appear. Use the UP and DOWN keys to input the amount of fuel you added to the tank and press MENU.

14.Repeat these steps for each fuel flow you want to calibrate.

NOTE:

It is a good idea to check the calibration of a fuel flow periodically.

Reset Calibration

The Reset Calibration command allows you to reset a fuel flow back to factory default settings.

To execute Reset Calibration command:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. Select the fuel flow you want to reset and press MENU.

3.Select RST CAL from the fuel flow menu and press MENU. The following message will appear: Hit Menu to Rst the Cal.

4.Press MENU to set calibration back to factory default settings. To recalibrate the fuel flow, follow the steps in the previous segment regarding fuel flow calibration.

Partial Fill

You will use the Partial Fill option each time you add fuel but do not fill up the tank.

To use Partial Fill:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight FUEL MNGR and press MENU. Select PART FILL. and press MENU. The Select Tank menu will open with three options: Port, Cen