Level Warning:

A Level Warning alerts you when the fluid level rises above or falls below a preset percentage of tank capacity. The Level Warning menu has two options: Low Level and High Level. A low level warning is used for fluid types like fuel, oil and freshwater, whereas a high level warning is best suited for black water and Waste Water (Gray Water).

To set a Level Warning:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select a configured fluid level and press MENU, which will open the Configuration Options menu. Highlight LEV WRNG and press MENU.

3.The Select Level menu will appear with two options: Low Level and High Level.

NOTE:

If you configure a tank for fuel, you should choose a LOW LEVEL warning, which will warn you when the fuel level drops below a preset percentage of the tank's capacity. A Low Level alarm will also work best for Fresh Water and Oil configurations. When a tank is configured for Black Water or Waste Water, the Level Warning should be set to the High Level. If, for example, you set the High Level warning to 3 Quarters of a tank (75 percent), you would be alerted before the tank's capacity had been exceeded, allowing you to empty the tank before it fills up.

4.Highlight the desired level and press MENU. The Level Percentage dialog box will appear. It will be set to Off by default.

5.Use the UP and DOWN keys to set the level warning to a desired percentage of tank capacity and press MENU. You will be taken back to the Bus Devices list.

Reset

The Reset command will reset all values for a device, including configuration and calibration settings.

To execute Reset command:

1.Press MENU, select SYSTEM SETUP and press MENU. Highlight B. DEVICES and press MENU.

2.Select a configured fluid level and press MENU, which will open the Configuration Options menu.

3.Highlight RESET and press MENU. The following message will appear: Hit Menu to Rst Values.