Lowrance electronic LMF-200 manual EP-35 Temperature Configuration, To configure EP-35 Temp Sensor

Models: LMF-200

1 72
Download 72 pages 48.35 Kb
Page 39
Image 39

Section 4: EP Configuration &

Calibration

To configure items connected to the LowranceNET network, press MENU and select SYSTEM SETUP. Highlight B. DEVICES and press MENU, which will open the Bus Devices list, a list of devices on the network. Bus Devices works as the device manager for the bus, allowing you to configure and unconfigure devices and set and reset critical values such as alarms and calibration.

If you configure or reconfigure a sensor, you are assigning or reassigning its configuration name in the LMF-200 to a different sensor location on the boat.

NOTE:

The Suzuki Engine Interface, EP-10 Fuel Flow, EP-15 Fluid Level, EP-35 Temperature Sensor and EP-50 Storage Device are the only devices that can be configured through the Bus Devices list.

The following items can be configured, unconfigured or reconfigured: Temperature (UnCfg Tmp), Fuel Flow (UnCfg FF) and Fluid Level (UnCfg FL) sensors. When they are shown on the bus devices list as UnCfg Tmp, UnCfg FF and the UnCfg FL, they are unconfigured.

You can have multiple Temperature sensors and Fluid Level Tanks, but will have no more than three Fuel Flows to configure since the LMF-200 supports a maximum of three engines on a vessel.

NOTE:

If you configure the desired sensors and are not satisfied with the results, you may clear the configuration settings for each sensor individually, by resetting values from the sensor's configuration menu. Remember, ONLY the sensor you select from the Bus Devices list will be set back to its defaults.

EP-35 Temperature Configuration

The EP-35 Temperature sensor has three configuration options: Inside, Outisde and Water. An unconfigured temperature sensor will appear on the Bus Devices list as UnCfg Temp.

To configure EP-35 Temp Sensor:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. After a few moments the Bus Devices list, a list of devices on the network, will appear.

33

Page 39
Image 39
Lowrance electronic LMF-200 manual EP-35 Temperature Configuration, To configure EP-35 Temp Sensor