Configuring the Cajun P550 Switch (Layer 2 & Layer 3)
SettingTo set Summer Time Hours that are not based on a standard rule:
1.In the System Information section of the Web Agent window, click System Clock. The System Clock dialog box opens.
2.In Clock Options, click Summer Time Hours Algorithm. The Summer Time Hours Configuration box opens.
3.From the Enable State
4.In the Offset cell of the Value column, enter the reset value for the clock in minutes.
For example, if you intend to reset the clock forward or backward by one hour, retain the default value of 60 minutes.
5.Click
Note: The Web Agent enables you to select the boxes next to both Recurring and
6.Use Table
| Table | |
|
|
|
Parameter |
| Definition |
|
|
|
| Select if Summer Time Hours change one time, such as on | |
|
| a specified date. |
|
| When you select |
|
| indicate the time and date on which Summer Time Hours |
|
| begin and end. |
|
|
|
Start |
| Specifies the start of Summer Time Hours. |
|
|
|
End |
| Specifies the end of Summer Time Hours. |
|
|
|
Cajun P550/P220 Switch Operation Guide |