Configuring the Cajun P550 Switch (Layer 2 & Layer 3)
Note: The supervisor modules shut down the switching modules if the temperature reaches the Shutdown temperature. The modules are restarted if the temperature goes below the Upper Warning Temperature. The default Shutdown temperatures are conservative for the slot 1 sensor (50° C) and backplane sensor (50° C). They can be safely set to 60° C, but settings higher than 60° C are not recommended. You can set the shutdown temperature to a value lower than 50° C to ensure prompt notification if a fan fails.
Displaying the Power System StatisticsTo display the power system statistics:
1.In the System Information section of the Web Agent window, click Power System. The Power System dialog box opens.
2.Use Table
Table | |
|
|
Parameter | Definition |
|
|
Power Supply | Identifies the power supply. |
|
|
Status | Identifies whether the power supply is detected. |
|
|
Type | Describes the type of power supply detected. |
|
|
Total System Power | Displays the total system power in Watts. |
|
|
Current Power Available | Displays the current power available. |
|
|
Note: The power system settings will only display 600W of available power with three power supplies installed. This is because the switch uses a maximum of two power supplies. The third power supply is held in reserve for redundancy in the event one of the other power supplies fails.
Displaying Cooling System StatisticsTo display the switch’s cooling system status:
1.In the System Information section of the Web Agent window, click Cooling System. The Cooling System dialog box opens.
2.Ensure that all the individual components are operational by checking the status column for each component.
3.If a component’s status is