SECTION 7. ELECTRICAL INFORMATION
| MACHINE | MACHINE | VOLTAGE- |
| |
| CONTROL | CONTROL |
| ||
FUNCTION | APPROX. | TIMER CONTACT | |||
BOARD | BOARD | ||||
| (When Activated) |
| |||
| TERMINAL/WIRE | TERMINAL/WIRE |
| ||
|
|
| |||
|
|
|
|
| |
Colors | Line Relay NO | P3/2 (PK 37) | 24 VDC | Not Involved | |
(Fabric Switch) | (GY 26) | ||||
|
|
| |||
|
|
|
|
| |
Delicates | Line Relay NO | P3/6 (OR 38) | 24 VDC | Not Involved | |
(Fabric Switch) | (GY 26) | ||||
|
|
| |||
|
|
|
|
| |
Hand Washables | Line Relay NO | P3/8 (BR 39) | 24 VDC | Not Involved | |
(Fabric Switch) | (GY 26) | ||||
|
|
| |||
|
|
|
|
| |
Whites | Line Relay NO | P3/2 (PK 37) | 0 VDC |
| |
P3/6 (OR 38) | 0VDC | Not Involved | |||
(Fabric Switch) | (GY 26) | ||||
P3/8 (BR 39) | 0VDC |
| |||
|
|
| |||
|
|
|
|
| |
Signal ON/OFF | Line Relay NO | P2/1 (PU 21) | 24 VDC - ON | Not Involved | |
(Options Switch) | (GY26) | 0 VDC - OFF | |||
|
| ||||
|
|
|
|
| |
Extrac Rinse | P5 (WH 11) | P7/8 (PK 19) | 120 VAC | 12B (GY 22) | |
(Options Switch) | |||||
|
|
|
| ||
|
|
|
|
| |
Stain Cycle | Line Relay NO | P3/* (BR39) | 24 VDC | Not Involved | |
(Options Switch) | (GY 26) | ||||
|
|
| |||
|
|
|
|
| |
Max Extract | Line Relay NO | P2/3 YL 20) | 24 VDC | Not Involved | |
(Options Switch) | (GY26) | ||||
|
|
| |||
|
|
|
|
| |
Push To Start |
| P1/3 (YL 28 or |
|
| |
Switch | P5 (WH 11) | 120 VAC | Not Involved | ||
RD 28) | |||||
(When Pressed) |
|
|
| ||
|
|
|
| ||
|
|
|
|
| |
Unbalance Control | Line Relay NO | P2/4 (OR 40) | 24 VDC | Not Involved | |
(GY 26) | |||||
|
|
|
| ||
|
|
|
|
| |
Door Lock - Spin | P3 (1) | P3/7 (YL 36) | 24 VDC | Not Involved | |
|
|
|
|
| |
Machine Control & |
| Line Relay Com |
|
| |
Motor Control | P5 (WH11) | 120 VAC | Not Involved | ||
(BK 27) | |||||
Power |
|
|
| ||
|
|
|
| ||
|
|
|
|
| |
Hot Water Valve | P5 (WH11) | P7/1 (OR7) | 120 VAC or | Not Involved | |
|
|
|
| ||
|
|
|
|
| |
Cold Water Valve | P5 (WH11) | P7/2 (BU 9) | 120 VAC or | Not Involved | |
|
|
|
| ||
|
|
|
|
| |
Door Lock Wax | P5 (WH11) | P7/4 (BR 14) | 120 VAC | Not Involved | |
Motor | |||||
|
|
|
| ||
|
|
|
|
| |
Bleach Water | P5 (WH11) | Not Involved | 120 VAC | 2T (BR 5) | |
Valve | |||||
|
|
|
| ||
|
|
|
|
| |
Softener Water | P5 (WH11) | Not Involved | 120 VAC | 2B (YL 6) | |
Valve | |||||
|
|
|
| ||
|
|
|
|
| |
Delay Light | Line Relay NO | Not Involved | 120 VAC | 4T (OR 2) | |
(GY 26) | |||||
|
|
|
| ||
|
|
|
|
|
16010199 | 8 |
Revised 7/00 | ©2000 Maytag Appliances Sales Company |