Help | Description | Trigger | Action to be Taken | |
Code | ||||
|
|
| ||
|
|
|
| |
16 | Spin suds lock | Suds lock, full on for | Too much detergent; | |
|
| 1 second within a | with suds suppressor being used; | |
|
| spin at less than 500 | washing clothes with minimal amount of | |
|
| rpm during a spin | soils present with normal measure | |
|
| cycle | amount of detergent | |
|
|
|
| |
17 | (Not used) |
|
| |
|
|
|
| |
18 | (Not used) |
|
| |
|
|
|
| |
19 | Power down | Loss of power | LED washer will also display"PF" | |
|
|
|
| |
20 | (Not Used) |
|
| |
|
|
|
| |
21 | Fast fill | Fill level reached | Possible slow drain scenario present or | |
|
| within 2 seconds of | customer interrupted wash cycle and | |
|
| fill initation | started washer over again. Check for | |
|
|
| Diagnostic Code 08 | |
|
|
|
| |
22 | (Not used) |
|
| |
|
|
|
| |
23 | Too much power | Motor on at full | Informative Only | |
| at | power for 30 seconds |
| |
|
| between |
| |
|
|
|
| |
(Not used) |
|
| ||
|
|
|
| |
(Not used) |
|
| ||
|
|
|
| |
33 | Excessive Subs | Control board detects | Too much detergent; | |
| Detected During | motor torque | with suds suppressor being used; | |
| wash/tumble | fluctuations dropping | washing clothes with minimal amount of | |
|
| in torque readings | soils present with normal measure | |
|
|
| amount of detergent | |
|
|
|
| |
34 | Too much power | Maximum torque | Perform Diagnostic Motor/Motor | |
| at start of spin | requested in spin less | Control Board test. Check wire harness | |
|
| than 450 rpm | connections at motor, motor control | |
|
|
| board (JP4 connector) and machine | |
|
|
| control board connection | |
|
|
|
| |
35 | Too much power | Maximum torque | Perform Diagnostic Motor/Motor | |
| during | requested in | Control Board test. Check wire harness | |
| wash/tumble | wash/tumble | connections at motor, motor control | |
|
|
| board (JP4 connector) and machine | |
|
|
| control board connections | |
|
|
|
| |
36 | Motor still running | Motor still running | Informative only | |
| after 120 seconds | after 120 seconds of |
| |
| of coast down | coast down after a |
| |
| after a spin | spin |
| |
|
|
|
| |
37 | Motor running too | 1 minute after start of | Informative only | |
| fast during tumble | tumble, if speed is > |
| |
| for too long | 85 rpm. |
| |
|
|
|
|
16010486 | Section 3. Teardown & Wiring Information | |
| ||
Revised 2/01 | ©2001 Maytag Appliances Sales Company |
|