Wireless Gateway User Guide

Dial-in

Enable dial-in access

Use this to suspend or enable dial-in access.

 

This setting can also be changed on the Dial-in Users screen.

 

 

Enforce connection

If checked, the Wireless Gateway will terminate the Dial-in

time limit

connection after the specified period. The time period can be set

 

from 1 to 999 minutes.

 

If unchecked, the connection time-out set on the Serial Port

 

screen will be used. If neither time-out is enabled, the connection

 

must be terminated by the remote user.

 

 

Call back

Select the desired option:

 

Disabled:- The user can simply dial-in; the Wireless Gateway

 

 

will not hang-up and call back.

 

Roaming:- After providing their name and password, the user

 

 

is prompted for the call-back number. The Wireless Gateway

 

 

will then hang up and dial the number provided by the remote

 

 

user.

 

Fixed:- The number entered in the Telephone No. field is

 

 

always used as the call-back number. The Wireless Gateway

 

 

will accept the incoming call, authenticate the user, then hang

 

 

up and dial this number.

 

Telephone No:- If Fixed is chosen, a telephone number must

 

 

be entered in this field. For the other options, this field is ig-

 

 

nored.

 

 

 

50

Page 53
Image 53
Milan Technology MIL-W0311, MIL-W1311 manual Enable dial-in access, Enforce connection, Time limit, Call back