Function | Parameters | Name | Setting Range | Increments | Initial Value | Refer to | |||
page | |||||||||
|
|
|
|
|
|
|
| ||
|
|
| 135 | Commercial | 0, 1 | 1 | 0 | 39 | |
Commercialpower |
|
| sequence output terminal selection | ||||||
|
|
|
|
|
| ||||
139 | between inverter and commercial power- | 0 to 60Hz, 9999 | 0.01Hz | 9999 | 39 | ||||
|
|
| 136 | MC switchover interlock time | 0 to 100s | 0.1s | 1s | 39 | |
|
|
| 137 | Waiting time at a start | 0 to 100s | 0.1s | 0.5s | 39 | |
|
|
| 138 | Commercial | 0, 1 | 1 | 0 | 39 | |
|
|
| switchover selection at an alarm | ||||||
|
|
|
|
|
|
|
| ||
|
|
|
| Automatic switchover frequency |
|
|
|
| |
|
|
|
| supply operation |
|
|
|
| |
|
|
| 140 | Backlash acceleration stopping | 0 to 400Hz | 0.01Hz | 1Hz | 30 | |
Backlash measures | frequency | ||||||||
|
|
|
|
| |||||
142 | frequency | 0 to 400Hz | 0.01Hz | 1Hz | 30 | ||||
|
|
| 141 | Backlash acceleration stopping time | 0 to 360s | 0.1s | 0.5s | 30 | |
|
|
|
| Backlash deceleration stopping |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
| 143 | Backlash deceleration stopping time | 0 to 360s | 0.1s | 0.5s | 30 | |
|
|
| 144 | Speed setting switchover | 0, 2, 4, 6, 8, 10, 102, 104, | 1 | 4 | 31 | |
| |
| 106, 108, 110 | ||||||
|
|
|
|
|
|
|
| ||
| PU |
| 145 | PU display language selection | 0 to 7 | 1 | 0 | 40 | |
|
|
|
|
|
|
|
|
| |
| detection |
| 148 | Stall prevention level at 0V input. | 0 to 150% | 0.1% | 120% | 30 | |
|
| 149 | Stall prevention level at 10V input. | 0 to 150% | 0.1% | 150% | 30 | ||
|
|
| |||||||
|
|
| 150 | Output current detection level | 0 to 150% | 0.1% | 120% | 40 | |
| Current |
| 151 | Output current detection signal delay | 0 to 10s | 0.1s | 0s | 40 | |
|
| time | |||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
|
|
| 152 | Zero current detection level | 0 to 150% | 0.1% | 5% | 40 | |
|
|
| 153 | Zero current detection time | 0 to 1s | 0.01s | 0.5s | 40 | |
|
|
| 154 | Voltage reduction selection during stall | 0, 1 | 1 | 1 | 30 | |
| |
| prevention operation | ||||||
|
|
|
|
|
|
|
| ||
| |
| 155 | RT signal reflection time selection | 0, 10 | 1 | 0 | 40 | |
| |
| 156 | Stall prevention operation selection | 0 to 31, 100, 101 | 1 | 0 | 30 | |
| |
| 157 | OL signal output timer | 0 to 25s, 9999 | 0.1s | 0s | 30 | |
|
|
| 158 | AM terminal function selection | 1 to 3, 5, 6, 8 to 14, 17, 21, | 1 | 1 | 32 | |
| |
| 24, 50, 52, 53 | ||||||
|
|
|
|
|
|
|
| ||
|
|
| 159 | Automatic switchover ON range | 0 to 10Hz, 9999 | 0.01Hz | 9999 | 39 | |
| |
| between commercial | ||||||
|
|
|
| inverter operation |
|
|
|
| |
| |
| 160 | User group read selection | 0, 1, 9999 | 1 | 9999 | 40 | |
|
|
| 161 | Frequency setting/key lock operation | 0, 1, 10, 11 | 1 | 0 | 41 | |
| |
| selection | ||||||
|
|
|
|
|
|
|
| ||
|
|
| 162 | Automatic restart after instantaneous | 0, 1, 10, 11 | 1 | 0 | 33 | |
Automatic |
| functions | power failure selection | ||||||
restart |
|
|
|
|
| ||||
163 | First cushion time for restart | 0 to 20s | 0.1s | 0s | 33 | ||||
|
|
| |||||||
|
|
| 164 | First cushion voltage for restart | 0 to 100% | 0.1% | 0% | 33 | |
|
|
| 165 | Stall prevention operation level for | 0 to 150% | 0.1% | 120% | 33 | |
|
|
| restart | ||||||
|
|
|
|
|
|
|
| ||
Current detection | 167 | Output current detection signal retention | 0, 1 | 1 | 0 | 40 | |||
selection | |||||||||
|
|
| 166 | time | 0 to 10s, 9999 | 0.1s | 0.1s | 40 | |
|
|
|
| Output current detection operation |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| |
| 168 | Parameter for manufacturer setting. Do not set. |
|
|
| ||
| |
| 169 |
|
|
| |||
|
|
|
|
|
|
| |||
Cumulative | monitor |
| 170 | Cumulative power meter clear | 0, 10, 9999 | 1 | 9999 | 32 | |
clear | 171 | Operation hour meter clear | 0, 9999 | 1 | 9999 | 32 | |||
|
|
| |||||||
|
|
|
|
|
|
|
|
| |
User group | 172 | User group registered display/batch | 9999, (0 to 16) | 1 | 0 | 40 | |||
clear | |||||||||
|
|
|
|
| |||||
173 | User group registration | 0 to 999, 9999 | 1 | 9999 | 40 | ||||
|
|
| |||||||
|
|
| 174 | User group clear | 0 to 999, 9999 | 1 | 9999 | 40 |
|
| Features |
|
| |
|
|
| |||
|
|
| |||
Peripheral Devices | Why energy | savings? | |||
|
|
|
|
|
|
| Standard | Specifications |
| ||
|
|
|
|
|
|
Outline | Dimension | Drawings | |||
|
|
|
|
|
|
|
|
|
|
|
|
Terminal Connection | Diagram | Terminal Specification | Explanation | ||
|
|
|
|
|
|
| Operation | Panel |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Parameter | List |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
Explanations | of | Parameters | |||
|
|
|
|
|
|
| Protective | Functions |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Options |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Instructions |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Motor |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Compatibility |
|
| |
|
|
|
|
|
|
|
| Warranty |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inquiry |
|
| |
|
|
|
|
|
|
24