Protective Functions

When an alarm occurs in the inverter, the protective function is activated bringing the inverter to an alarm stop and the PU display automatically changes to any of the following error (alarm) indications.

Error message *2

Warnings *3

Minor fault *4

Major failures *5

Function Name

 

 

Description

Indication

Operation panel lock

Appears when operation is tried during operation panel lock.

 

Parameter write error

Appears when an error occurs at parameter writing.

to

 

 

 

 

 

 

Copy operation error

Appears when an error occurs at parameter copying.

to

 

 

 

 

 

Error

Appears when the RES signal is on or the PU and inverter can not make normal

 

communication.

 

 

Stall Prevention

 

 

Appears during overcurrent stall prevention.

 

(overcurrent)

 

 

 

 

 

Stall prevention

Appears during overvoltage stall prevention

 

(overvoltage)

Appears while the regeneration avoidance function is activated.

 

 

Appears if the regenerative brake duty reaches or exceeds 85% of the Pr. 70 "special

 

Regenerative brake

regenerative brake duty" value. If the regenerative brake duty reaches 100%, a

 

prealarm

regenerative overvoltage (E. OV_) occurs.

 

 

(displayed only for the 75K or more)

 

Electronic thermal relay

Appears when the electronic thermal O/L relay has reached 85% of the specified

 

function prealarm

value.

 

 

PU Stop

Appears when

 

on the operation panel was pressed during external operation.

 

 

 

Maintenance signal output

Appears when the cumulative energization time has exceeded the maintenance

 

output timer set value.

 

 

 

Parameter copy

Appears when parameters are copied between models with capacities of 55K or

 

less and 75K or more.

 

 

 

Fan fault

Appears when the cooling fan remains stopped when operation is required or when the speed

 

has decreased.

 

 

 

 

 

Overcurrent shut-off during

Appears when an overcurrent occurred during acceleration.

 

acceleration

 

 

 

 

 

Overcurrent shut-off during

Appears when an overcurrent occurred during constant speed operation.

 

constant speed

 

 

 

 

 

Overcurrent shut-off during

Appears when an overcurrent occurred during deceleration and at a stop.

 

deceleration or stop

 

 

 

 

 

Regenerative overvoltage

Appears when an overvoltage occurred during acceleration.

 

shutoff during acceleration

 

 

 

 

 

Regenerative overvoltage

 

 

 

 

shut-off during constant

Appears when an overvoltage occurred during constant speed operation.

 

speed

 

 

 

 

Regenerative overvoltage shut-

Appears when an overvoltage occurred during deceleration and at a stop.

 

off during deceleration or stop

 

 

 

 

Inverter overload shut-off

Appears when the electronic thermal relay function for inverter element protection

 

(electronic thermal relay

 

was activated.

 

 

function)*1

 

 

 

 

 

 

Motor overload shut-off

Appears when the electronic thermal relay function for motor protection was

 

(electronic thermal relay

 

activated.

 

 

function)*1

 

 

 

 

 

 

Fin overheat

Appears when the heatsink overheated.

 

Instantaneous power failure

Appears when an instantaneous power failure occurred at an input power supply.

 

protection

 

 

 

 

 

Undervoltage protection

Appears when the main circuit DC voltage became low.

 

Input phase failure

Appears if one of the three phases on the inverter input side opened.

 

Stall prevention

Appears when the output frequency drops to 0.5Hz as a result of deceleration due to

 

the excess motor load.

 

 

 

Output side earth (ground)

Appears when an earth (ground) fault occurred on the inverter's output side.

 

fault overcurrent protection

 

 

 

 

 

Output phase failure

Appears if one of the three phases on the inverter output side opened.

 

protection

 

 

 

 

 

External thermal relay

Appears when the external thermal relay connected to the terminal OH operated.

 

operation *6

 

 

 

 

 

PTC thermistor operation

Appears when the motor overheat status is detected for 10s or more by the external

 

PTC thermistor input connected to the terminal AU.

 

 

 

 

Appears when an alarm occurred in the option card or an AC power supply is

 

Option alarm

connected to the R/L1, S/L2, T/L3 when the high power factor converter connection

 

 

is set.

 

 

Option slot alarm

Appears when a communication error occurred in the communication option.

 

Option alarm

Appears when a functional error occurred in the plug-in option.

 

Parameter storage devide

Appears when operation of the element where parameters are stored became

 

alarm

abnormal. (control circuit board)

 

47