Option and Peripheral Devices
Options
By fitting the following options to the inverter, the inverter is provided with more functions. One
| Name | Type |
| Applications, Specifications, etc. |
| Applicable | ||
|
|
| Inverter | |||||
|
|
|
|
|
|
| ||
|
|
| ⋅ | This input interface sets the high frequency accuracy of the |
| |||
|
|
|
| inverter using an external BCD or binary digital signal. |
|
| ||
|
| BCD code 3 digits (maximum 999) |
|
| ||||
| BCD code 4 digits (maximum 9999) |
|
| |||||
|
|
|
|
|
| |||
|
|
|
| Binary 12 bits (maximum FFFH) |
|
| ||
|
|
|
| Binary 16 bits (maximum FFFFH) |
|
| ||
|
|
| ⋅ | This option provides the inverter with open collector outputs |
| |||
|
|
|
| selected from among the standard output signals. |
|
| ||
Digital output |
| ⋅ | This option adds two | different signals that can | be |
| ||
extension analog output |
| monitored at the terminals FM and AM, such as the output | Shared among all | |||||
|
| |||||||
|
|
|
| frequency, output voltage and output current. |
| models | ||
|
|
| ⋅ | 20mADC or 5VDC (10V) meter can be connected. |
|
| ||
Relay output |
| ⋅ | Output any three output signals available with the inverter |
| ||||
| as standard from the relay contact terminals |
|
| |||||
|
|
|
|
|
| |||
Communication | LONWORKS |
| only. |
|
|
| ||
|
|
| ⋅ | This option allows the inverter to be operated or monitored |
| |||
|
|
|
| or the parameter setting to be changed from a computer or |
| |||
|
|
|
| PLC. |
|
|
| |
|
|
| * For the |
| ||||
|
|
| Interactive parameter unit with LCD display |
|
| |||
Parameter unit (Eightlanguages) |
|
| ||||||
Parameter unit connection cable | Cable for connection of operation panel or parameter unit |
| Shared among all | |||||
indicates a cable length. (1m, 3m, 5m) |
| |||||||
|
|
|
| models | ||||
Operation panel connection | Connector to connect the operation panel |
| ||||||
|
| |||||||
connector | connection cable |
|
|
| ||||
|
|
|
| |||||
|
|
| Attachment for replacing | with the F700 series using | the |
| ||
|
| installation holes of the |
|
| ||||
|
|
|
| According to | ||||
Intercompatibility attachment |
|
|
|
|
| |||
| Attachment for replacing with the F700 series using the | capacities | ||||||
|
| |||||||
|
| installation holes of the |
| |||||
|
|
| A200<Excellent> |
|
|
| ||
AC reactor |
| For harmonic current reduction and inverter input power factor | For 200V class | |||||
55K or less, 400V | ||||||||
|
|
| improvement (total power factor approx. 88%) |
| class 75K or less | |||
|
|
|
|
|
|
| ||
DC reactor |
| For harmonic current reduction and inverter input power factor | For the 55K or | |||||
improvement (total power factor approx. 93%) |
| less | ||||||
|
|
|
| |||||
Line noise filter | FR- BSF01 | For line noise reduction |
|
| Shared among all | |||
FR- BLF |
|
| models | |||||
|
|
|
|
|
| |||
BU type brake unit | BU | For increasing the braking capability of the inverter (for high- | For the 55K or | |||||
inertia load or negative load) |
| less | ||||||
|
|
|
| |||||
Brake unit | For increasing the braking capability of the inverter (for high- |
| ||||||
According to | ||||||||
|
|
| inertia load or negative load) |
| capacities | |||
Resistor unit | Brake unit and resistor unit are used in combination |
| ||||||
|
| |||||||
|
|
|
|
|
|
| ||
Power regeneration common |
|
|
|
|
|
| ||
converter | Unit which can return | For the 55K or | ||||||
| ||||||||
Dedicated |
| to the power supply in common converter system |
| less | ||||
for the |
|
|
|
|
| |||
|
|
|
|
|
| |||
Power regeneration converter |
| Energy saving type high performance brake unit which can | For the 75K or | |||||
regenerate the braking energy generated by the motor to the | more | |||||||
|
|
| power supply. |
|
|
| ||
|
|
| The high power factor converter switches the converter | According to | ||||
High power factor converter | section on/off to reshape an input current waveform into a | |||||||
| sine wave, greatly suppressing harmonics. (Used in | capacities | ||||||
|
| |||||||
|
|
| combination with the standard accessory.) |
|
| |||
Surge voltage suppression filter |
| Filter for suppressing surge voltage on motor |
| For 400V class | ||||
| 55K or less | |||||||
|
|
|
|
|
|
| ||
Sinewave filter | Reactor | Reduce the motor noise during inverter driving |
| For the 75K or | ||||
|
|
| ||||||
Capacitor | Use in combination with a reactor and a capacitor |
| more | |||||
|
|
|
| |||||
|
|
|
|
|
|
|
|
49