Mitsubishi Electronics FR-F700 High power factor, Converter Outline dimension Unit mm FR-HC- HK

Models: FR-F700

1 65
Download 65 pages 14.03 Kb
Page 54
Image 54

Name (type)

Specifications, Structure, etc.

￿Enables 100%-torque continuous regeneration to support continuous regenerative

 

operation for line control, etc.

 

 

 

 

 

 

 

 

 

 

 

FR-CV-(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ Eliminates the need to use a brake unit with each inverter, reducing total space and total

 

 

 

 

 

 

 

FR-CV-(H)-AT

 

cost.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ Saves energy since regeneration energy is used for the other inverters and excess

 

 

 

 

 

 

 

 

 

 

 

energy is returned to the power supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ Connection example

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

R/L1

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S/L2

*1

V

IM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R1/L11

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dedicated stand-alone

FR-CV type

 

S1/L21

 

 

 

W

 

 

 

D1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reactor (FR-CVL)

Power regeneration

Inverter

 

 

 

 

 

 

D

 

 

 

D1

 

Power regeneration

MCCB

MC1

 

common converter

 

 

 

 

 

 

 

 

W

 

 

 

 

R2/L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Three-phase

R/L11

R2/L12

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

common converter

 

S/L21

S2/L22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

T2/L3

 

N/L

N/*2

 

 

 

 

 

 

 

 

 

 

 

 

T/L31

T2/L32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC power

 

 

S2/L2

 

P/L+

P/+

 

 

 

 

 

 

 

 

 

 

 

 

 

FR-CV-(H)￿￿K

 

 

 

 

 

 

 

 

 

 

FR-CV-(H)

 

 

 

 

 

 

 

(Unit mm)

 

 

 

R/L11

 

P24

PC

 

 

 

Voltage/

W

D

D1

H

Voltage/

W

D

D1

H

 

 

 

 

 

SD

SD

 

 

 

Capacity

Capacity

 

 

 

 

S/L21

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RDYA

 

 

 

 

2 7.5K/11K

90

303

103

300

4 7.5K/

 

 

 

 

 

 

 

 

T/MC1

 

 

 

 

120

305

105

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RDYB

X10 *3

 

 

0 15K

120

305

105

300

0 11K/15K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RSO

RES

 

 

 

0 22K/30K

150

322

122

380

0 22K/30K

150

305

105

380

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SE

 

 

 

 

V 37K/55K

400

250

135

620

V 37K/55K

400

250

135

620

 

 

 

 

 

 

 

 

 

 

 

 

*1. Remove the jumpers across terminals R/L1-R1/L11 and S/L2-S1/L21 of the inverter, and

FR-CV-(H)-AT

 

 

 

 

 

 

(Unit mm)

 

connect the control circuit power supply across terminals R1/L11-S1/L21. Always keep

Voltage/

W

D

D1

H

Voltage/

W

D

D1

H

 

the power input terminals R/L1, S/L2, T/L3 open. Incorrect connection will damage the

Capacity

Capacity

 

inverter. Opposite polarity of terminals N/-, P/+ will damage the inverter.

 

 

2 7.5K/11K

110

315

115

330

4 7.5K/

 

 

 

 

 

*2. Do not insert an NFB between the terminals P/+-N/- (between P/L+-P/+, between N/

130

320

120

330

 

0 15K

130

320

120

330

0 11K/15K

 

L--N/-).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

0

 

 

 

 

 

*3. Assign the terminal for X10 signal using any of Pr. 178 to Pr. 189 (input terminal

160

350

150

410

160

350

150

410

 

V 22K/30K

V 22K/30K

 

function selection).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*4. Be sure to connect the power supply and terminals R/L11, S/L21, T/MC1. If the inverter is

 

 

 

 

 

 

 

 

 

 

 

operated without connection, the power regeneration common converter will be damaged.

 

 

 

 

 

 

 

 

 

 

 

￿ Substantially suppresses power harmonics to realize the equivalent

 

￿ Has the power regeneration function as standard.

 

 

 

 

 

capacity conversion coefficient K5=0 in the "Harmonic suppression

 

￿ Connects multiple inverters to enable common converter system

 

 

guideline for specific consumers".

 

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

 

 

￿Specifications

 

Inverter Type

 

 

 

 

200V

 

 

 

400V

 

 

 

 

 

 

FR-HC￿￿

 

 

7.5K

15K

30K

55K

H7.5K

H15K

H30K

H55K

 

 

 

 

Applied inverter capacity (*1)

3.7K to 7.5K 7.5K to 15K

15K to 30K

30K to 55K 3.7K to 7.5K

7.5K to 15K

15K to 30K

30K to 55K

 

 

 

Rated input voltage/

 

Three phase 200V to 220V 50Hz

 

 

Three phase

 

*1. The applicable capacity to the high

 

 

 

 

 

 

power factor converter is the total

 

frequency

 

 

 

200V to 230V 60Hz

 

 

380V to 460V 50/60Hz

 

 

 

 

 

 

 

 

capacity of the inverters.

 

Rated input current (A)

33

 

61

115

215

 

17

31

57

 

110

 

 

 

 

 

*2. The output voltage varies with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High power factor

Rated output voltage (V) (*2)

 

293VDC to 335VDC

 

 

558VDC to 670VDC

 

 

input voltage value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

converter

￿ Outline dimension

 

 

 

 

 

 

 

(Unit: mm)

 

 

 

FR-HC- (H)￿￿K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Power Factor

Reactor 1 FR-HCL01

Reactor 2 FR-HCL02

Outside Box FR-

 

 

 

 

 

Voltage

Capacity

Converter FR-HC

 

HCB

 

High power factor converter

Outside box

 

 

 

 

 

 

 

 

 

 

W H

D W H

D W H

D W H D

 

 

 

 

 

 

7.5K

 

 

 

 

 

2

220

300

190

160

155

100

240

230

160

190

320

165

 

 

H

H

 

15K

250

400

190

190

205

130

260

270

170

 

 

 

 

 

0

 

 

 

 

 

 

 

 

0

30K

340

550

195

220

230

170

340

320

180

270

450

203

 

W

D

 

 

V

55K

480

700

250

210

260

225

430

470

360

 

 

W

D

 

 

 

 

 

 

Reactor 1, Reactor 2

 

 

4

H7.5K

220

300

190

160

150

100

240

220

160

 

 

 

 

 

 

 

 

H15K

250

400

190

190

195

130

260

260

170

190

320

165

 

 

 

 

 

0

 

 

H

 

 

0

H30K

340

550

195

220

215

140

340

310

180

 

 

 

 

 

 

 

 

V

H55K

480

700

250

280

255

190

400

380

285

270

450

203

 

W

D

 

 

 

 

 

 

 

55