Main Differences and Compatibilities with the FR-F500(L) Series

Item

FR-F500 (L)

FR-F700

 

Simple mode parameters 61

Simple mode parameters 15

 

 

Pr. 0 Torque boost initial value

 

Pr. 0 Torque boost initial value

11K to 37K: 2%, 45K, 55K: 1.5%

 

(When the torque boost value of the FR-F500 series

 

11K to 55K: 2%

used was the initial value, it is not necessary to change

 

 

the torque boost value from the initial value when

 

 

replacing with the FR-F700 series.)

 

User group 1 (16), user group 2 (16)

User group (16) only

 

Setting methods were partially changed

 

(Pr. 160, Pr. 173 to Pr. 175)

 

(Pr. 160, Pr. 172 to Pr. 173)

 

 

 

 

"User initial value setting" (Pr. 199) was cleared

Changed/cleared

User initial value setting (Pr. 199)

Substitutable with the copy function of the operation

functions

 

panel (FR-DU07)

 

DC injection brake function with terminal (X13 signal)

DC injection brake function with terminal was cleared

 

(Pr. 11 setting value 8888, Pr. 180 to Pr. 186 setting

Start in reverse rotation is possible with flying start

 

function (frequency search of automatic restart after

 

value 13)

 

instantaneous power failure function)

 

 

 

Long wiring mode

Setting is not necessary

 

(Pr. 240 setting 10, 11)

(Pr. 240 settings "10" and "11" were cleared)

 

Intelligent optimum acceleration/deceleration

Function was cleared

 

For deceleration time, overvoltage alarm can be avoided

 

(Pr. 60 setting "3" and Pr. 61 to Pr. 63)

 

with regeneration avoidance function (Pr. 882 to Pr. 885).

 

 

 

Automatic torque boost

Automatic torque boost was cleared because of addition

 

(Pr. 38, Pr. 39)

of "Simple magnetic flux vector" (Pr. 80)

Terminal block

Removable terminal block

Removable terminal block

Priority compatibility (Terminal block of the F500 can be

 

 

mounted)

PU

FR-PU04, DU04

FR-DU07

FR-DU04 unavailable (Partly restricted when the FR-

 

 

PU04 is used.)

 

Dedicated plug-in

option (not compatible)

Plug-in option

Computer link, relay output option

Built into the inverter

FR-A5NR

(RS-485 terminals, relay output 2 points)

 

 

Three boards can be mounted

One board can be mounted

 

FR-F720-0.75K, 2.2K, 3.7K, 7.5K, 18.5K, 22K, 37K, 45K,

Installation size

FR-F740-0.75K to 3.7K, 7.5K, 22K, 37K to 55K are compatible in mounting dimensions

 

For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.

 

 

Features

 

 

 

 

 

 

 

 

Peripheral Devices

Why energy

savings?

 

 

 

 

 

 

 

Standard

Specifications

 

 

 

 

 

 

 

Outline

Dimension

Drawings

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Connection

Diagram

Terminal Specification

Explanation

 

 

 

 

 

 

 

Operation

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

List

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations

of

Parameters

 

 

 

 

 

 

 

Protective

Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatibility

 

 

 

 

 

 

 

 

 

 

Warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inquiry

 

 

 

 

 

 

 

 

64

Page 63
Image 63
Mitsubishi Electronics instruction manual FR-F500 L FR-F700