Function

Parameters

Name

 

Setting Range

Increments

Initial Value

Refer to

 

page

 

 

 

 

 

 

 

 

66

Stall prevention operation reduction

0 to 400Hz

0.01Hz

60Hz

30

starting frequency

 

 

 

 

 

 

 

Retry

67

Number of retries at alarm occurrence

0 to 10, 101 to 110

1

0

34

68

Retry waiting time

0 to 10s

0.1s

1s

34

 

 

69

Retry count display erase

0

 

1

0

34

70

Special regenerative brake duty *2

0 to 10%

0.1%

0%

31

71

Applied motor

0, 1, 2, 20

1

0

34

72

PWM frequency selection

0 to 15/0 to 6, 25*1

1

2

35

73

Analog input selection

0 to 7, 10 to 17

1

1

35

74

Input filter time constant

0 to

8

1

1

36

 

75

Reset selection/disconnected PU

0 to 3, 14 to 17

1

14

36

detection/PU stop selection

 

 

 

 

 

 

 

76

Alarm code output selection

0, 1,

2

1

0

36

77

Parameter write selection

0, 1,

2

1

0

36

78

Reverse rotation prevention selection

0, 1,

2

1

0

36

￿ 79

Operation mode selection

0, 1, 2, 3, 4, 6, 7

1

0

37

Simple fluxmagnetic controlvector

80

Motor capacity (simple magnetic flux

0.4 to 55kW, 9999

0.01/0.1kW*1

9999

37

vector control)

/0 to 3600kW, 9999*1

 

 

 

 

 

 

 

90

Motor constant (R1)

0 to 50Ω, 9999

0.001Ω/

9999

37

 

/0 to 400mΩ, 9999*1

0.01mΩ*1

 

 

 

 

 

 

 

 

 

 

 

 

 

100

V/F1 (first frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

V/F

101

V/F1 (first frequency voltage)

0 to 1000V

0.1V

0V

38

102

V/F2 (second frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

points

103

V/F2 (second frequency voltage)

0 to 1000V

0.1V

0V

38

 

5

104

V/F3 (third frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

Adjustable

105

V/F3 (third frequency voltage)

0 to 1000V

0.1V

0V

38

106

V/F4 (fourth frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

 

 

107

V/F4 (fourth frequency voltage)

0 to 1000V

0.1V

0V

38

 

108

V/F5 (fifth frequency)

0 to 400Hz, 9999

0.01Hz

9999

38

 

109

V/F5 (fifth frequency voltage)

0 to 1000V

0.1V

0V

38

 

117

PU communication station

0 to 31

1

0

38

connectorPU communication

118

PU communication speed

48, 96, 192, 384

1

192

38

123

PU communication waiting time setting

0 to 150ms, 9999

1

9999

38

 

119

PU communication stop bit length.

0, 1, 10, 11

1

1

38

 

120

PU communication parity check

0, 1, 2

1

2

38

 

121

Number of PU communication retries

0 to 10, 9999

1

1

38

 

122

PU communication check time interval

0, 0.1 to 999.8s, 9999

0.1s

9999

38

 

 

 

 

 

 

 

 

 

124

PU communication CR/LF presence/

0, 1, 2

1

1

38

 

absence selection

 

 

 

 

 

 

 

 

￿ 125

Terminal 2 frequency setting gain

0 to 400Hz

0.01Hz

60Hz

39

frequency

 

 

 

 

 

 

 

 

￿ 126

Terminal 4 frequency setting gain

0 to 400Hz

0.01Hz

60Hz

39

frequency

 

 

 

 

 

 

 

 

127

PID control automatic switchover

0 to 400Hz, 9999

0.01Hz

9999

39

 

freqeuncy

 

 

 

 

 

 

 

operation

128

PID action selection

10, 11, 20, 21, 50, 51, 60,

1

10

39

61

 

 

 

 

 

 

 

129

PID proportional band

0.1 to 1000%, 9999

0.1%

100%

39

 

 

130

PID integral time

0.1 to 3600s, 9999

0.1s

1s

39

PID

131

PID upper limit

0 to 100%, 9999

0.1%

9999

39

132

PID lower limit

0 to 100%, , 9999

0.1%

9999

39

 

 

133

PID action set point

0 to 100%, 9999

0.01%

9999

39

 

134

PID differential time

0.01 to 10.00s, 9999

0.01s

9999

39

*1 Differ according to capacities. (55K or less/75K or more) *2 Setting can be made for the 75K or more.

23

Page 22
Image 22