27
867 AM output filter 0 to 5s 0.01s 0.01s 32
872 Input phase failure protection selection 0, 1 1 0 42
Regeneration
avoidance function
882 Regeneration avoidance operation
selection 0, 1 1 0 45
883 Regeneration avoidance operation level 300 to 800V 0.1V 380V/760V*1 45
884 Regeneration avoidance at deceleration
detection sensitivity 0 to 5 1 0 45
885 Regeneration avoidance compensation
frequency limit value 0 to 10Hz, 9999 0.01Hz 6Hz 45
886 Regeneration avoidance voltage gain 0 to 200% 0.1% 100% 45
Free
parameter
888 Free parameter 1 0 to 9999 19999 45
889 Free parameter 2 0 to 9999 19999 45
Energy saving monitor
891 Cumulative power monitor digit shifted
times 0 to 4, 9999 19999 32
892 Load factor 30 to 150% 0.1% 100% 45
893 Energy saving monitor reference (motor
capacity) 0.1 to 55/0 to 3600kW*2 0.01/0.1kW*2 Inverter rated
capacity 45
894 Control selection during commercial
power-supply operation 0, 1, 2, 3 1 0 45
895 Power saving rate reference value 0, 1, 9999 19999 45
896 Power unit cost 0 to 500, 9999 0.01 9999 45
897 Power saving monitor average time 0, 1 to 1000h, 9999 19999 45
898 Power saving cumulative monitor clear 0, 1, 10, 9999 19999 45
899 Operation time rate (estimated value) 0 to 100%, 9999 0.1% 9999 45
Calibration parameters
C0
(900) FM terminal calibration 46
C1
(901) AM terminal calibration 46
C2
(902)
Terminal 2 frequency setting bias
frequency 0 to 400Hz 0.01Hz 0Hz 39
C3
(902) Terminal 2 frequency setting bias 0 to 300% 0.1% 0% 39
125
(903)
Terminal 2 frequency setting gain
frequency 0 to 400Hz 0.01Hz 60Hz 39
C4
(903) Terminal 2 frequency setting gain 0 to 300% 0.1% 100% 39
C5
(904)
Terminal 4 frequency setting bias
frequency 0 to 400Hz 0.01Hz 0Hz 39
C6
(904) Terminal 4 frequency setting bias 0 to 300% 0.1% 20% 39
126
(905)
Terminal 4 frequency setting gain
frequency 0 to 400Hz 0.01Hz 60Hz 39
C7
(905) Terminal 4 frequency setting gain 0 to 300% 0.1% 100% 39
989 Parameter copy alarm release 10/100 110/100*2 -
PU
990 PU buzzer control 0, 1 1 1 46
991 PU contrast adjustment 0 to 63 158 46
Clear
parameters
Pr.CL Parameter clear 0, 1 1 0 46
ALLC All parameter clear 0, 1 1 0 46
Er.CL Alarm history clear 0, 1 1 0 46
PCPY Parameter copy 0, 1, 2, 3 1 0 46