Function | Parameters | Name | Setting Range | Increments | Initial Value | Refer to | |
page | |||||||
|
|
|
|
|
| ||
| 867 | AM output filter | 0 to 5s | 0.01s | 0.01s | 32 | |
| 872 | Input phase failure protection selection | 0, 1 | 1 | 0 | 42 | |
Regeneration functionavoidance | 882 | Regeneration avoidance operation | 0, 1 | 1 | 0 | 45 | |
selection | |||||||
|
|
|
|
| |||
883 | Regeneration avoidance operation level | 300 to 800V | 0.1V | 380V/760V*1 | 45 | ||
| |||||||
| 884 | Regeneration avoidance at deceleration | 0 to 5 | 1 | 0 | 45 | |
| detection sensitivity | ||||||
|
|
|
|
|
| ||
| 885 | Regeneration avoidance compensation | 0 to 10Hz, 9999 | 0.01Hz | 6Hz | 45 | |
| frequency limit value | ||||||
|
|
|
|
|
| ||
| 886 | Regeneration avoidance voltage gain | 0 to 200% | 0.1% | 100% | 45 | |
Free parameter | 888 | Free parameter 1 | 0 to 9999 | 1 | 9999 | 45 | |
889 | Free parameter 2 | 0 to 9999 | 1 | 9999 | 45 | ||
| |||||||
|
|
|
|
|
|
| |
| 891 | Cumulative power monitor digit shifted | 0 to 4, 9999 | 1 | 9999 | 32 | |
| times | ||||||
|
|
|
|
|
| ||
monitor | 892 | Load factor | 30 to 150% | 0.1% | 100% | 45 | |
893 | Energy saving monitor reference (motor | 0.1 to 55/0 to 3600kW*2 | 0.01/0.1kW*2 | Inverter rated | 45 | ||
| |||||||
| capacity) | capacity | |||||
|
|
|
|
| |||
saving | 894 | Control selection during commercial | 0, 1, 2, 3 | 1 | 0 | 45 | |
| |||||||
|
|
|
|
|
| ||
Energy | 895 | Power saving rate reference value | 0, 1, 9999 | 1 | 9999 | 45 | |
897 | Power saving monitor average time | 0, 1 to 1000h, 9999 | 1 | 9999 | 45 | ||
| 896 | Power unit cost | 0 to 500, 9999 | 0.01 | 9999 | 45 | |
|
|
|
|
|
|
| |
| 898 | Power saving cumulative monitor clear | 0, 1, 10, 9999 | 1 | 9999 | 45 | |
| 899 | Operation time rate (estimated value) | 0 to 100%, 9999 | 0.1% | 9999 | 45 | |
| C0 | FM terminal calibration |
|
|
| 46 | |
| (900) | | | | |||
|
|
|
|
|
| ||
| C1 | AM terminal calibration |
|
|
| 46 | |
| (901) | | | | |||
|
|
|
|
|
| ||
| C2 | Terminal 2 frequency setting bias | 0 to 400Hz | 0.01Hz | 0Hz | 39 | |
| (902) | frequency | |||||
|
|
|
|
| |||
parameters | C3 | Terminal 2 frequency setting bias | 0 to 300% | 0.1% | 0% | 39 | |
(902) | |||||||
| |||||||
|
|
|
|
|
| ||
| 125 | Terminal 2 frequency setting gain | 0 to 400Hz | 0.01Hz | 60Hz | 39 | |
| (903) | frequency | |||||
|
|
|
|
| |||
Calibration | C4 | frequency | 0 to 300% | 0.1% | 100% | 39 | |
(904) | |||||||
| (903) | Terminal 2 frequency setting gain | |||||
| C5 | Terminal 4 frequency setting bias | 0 to 400Hz | 0.01Hz | 0Hz | 39 | |
|
|
| |||||
|
|
|
|
|
|
| |
| C6 | Terminal 4 frequency setting bias | 0 to 300% | 0.1% | 20% | 39 | |
| (904) | ||||||
|
|
|
|
|
| ||
| 126 | Terminal 4 frequency setting gain | 0 to 400Hz | 0.01Hz | 60Hz | 39 | |
| (905) | frequency | |||||
|
|
|
|
| |||
| C7 | Terminal 4 frequency setting gain | 0 to 300% | 0.1% | 100% | 39 | |
| (905) | ||||||
|
|
|
|
|
| ||
| 989 | Parameter copy alarm release | 10/100 | 1 | 10/100*2 | - | |
PU | 990 | PU buzzer control | 0, 1 | 1 | 1 | 46 | |
991 | PU contrast adjustment | 0 to 63 | 1 | 58 | 46 | ||
| |||||||
Clear parameters | Pr.CL | Parameter clear | 0, 1 | 1 | 0 | 46 | |
PCPY | Parameter copy | 0, 1, 2, 3 | 1 | 0 | 46 | ||
| ALLC | All parameter clear | 0, 1 | 1 | 0 | 46 | |
| Er.CL | Alarm history clear | 0, 1 | 1 | 0 | 46 | |
|
|
|
|
|
|
|
*1 The initial value differs according to the voltage class. (200V class / 400V class) *2 Differ according to capacities. (55K or less/75K or more)