326X Series Modem Troubleshooting Guide (Continued)

Problem

Diagnosis/Test

Possible Solution

Cannot hear connec-

Check Speaker (ATM) option.

If the speaker is not on, turn it on.

tion through the speaker

 

 

(stand-alone units)

 

 

 

Check Volume (ATL) option.

Adjust volume.

 

 

 

DATA MODE

 

 

The modem connects, Check that the modem is in data

but cannot pass data mode (“Data 9600”, for exam- ple, displays).

Check that the TD LED is lit on modem's front panel (steady or flashing) indicating that the modem is receiving data from the DTE.

If the modem is not in data mode, establish a connection with the remote modem.

Check DTE for EIA signal requirements.

Ensure the modem is correctly cabled to the DTE (with a straight-through cable for your electrical interface—V.35 or RS-232).

Check that the correct communications port is being used.

Check the DTE rate of the local modem.

Check the DTE's flow control method.

If in normal mode, check for modem-to-modem flow control.

Verify line quality:

Ensure that the DTE rate matches the modem’s terminal rate setting.

Ensure that the DTE's flow control is the same as the modem’s setting

(for example, XON-XOFF, RTS/CTS).

If your communications software package’s file transfer protocol is used, and the package supports RTS/CTS Flow control, set Flow=RTS/CTS

(AT*FL3). If the package does not support RTS/ CTS flow control, set Flow=Off (AT*FL0).

Turn modem flow control off.

Troubleshooting

 

• Run a remote digital

After running the RDL, if no errors occur, your line is

 

loopback (RDL) or RDL

good.

 

with pattern test.

If errors occur, perform a manual retrain, or retry the

 

 

 

 

phone call.

 

• If you are still receiving

If the LAL or LAL with pattern test fails, contact Motor-

 

errors, disconnect the

ola Customer Support.

 

modem from the line and

If the LAL or LAL with pattern test passes, you may have

 

perform a local analog

 

a line problem (contact your telephone company) or a

 

loopback (LAL) or LAL

 

problem with your application (check with your software

 

with pattern test (with

 

vendor).

 

modem flow control off).

 

 

 

 

 

Premature disconnect

Ensure that the remote modem

If the remote modem does not support error correction,

 

supports error correction.

set the modem to normal mode and retry the call.

 

Check the disconnect reason

Based upon the disconnect reason, take the appropriate

 

from the modem's front panel.

action.

 

 

 

Troubleshooting Guide 6-5