326X Series Modem Troubleshooting Guide (Continued)

Problem

Diagnosis/Test

Possible Solution

CALL TERMINA-

 

 

TION

 

 

Modem takes too long to

Check to see if remote modem

If remote modem doesn’t support PSTN cleardown, try to

disconnect

supports PSTN cleardown.

change the setting of DCD Loss Disconnect (AT*CD)

 

 

to a smaller number.

 

 

 

Modem doesn’t discon-

Check modem’s DTR option for

• Set DTR to an option other than High.

nect when DTR drops,

correct setting.

• Set DTR=Discon (AT&D2).

or

 

 

Modem doesn’t discon-

 

 

nect when communica-

 

 

tions software package

 

 

does

 

 

 

 

 

Communications soft-

Check the delay between issuing

Ensure the escape sequence (+++) complies with the

ware package won’t sig-

the escape sequence (+++) and

modem’s guard time requirements (refer to Line feed

nal the modem to return

the ATH command.

character:S-Register 4 for details).

to command state when

 

 

escape sequence (+++)

 

 

is issued

 

 

 

Check whether the modem is set

Set ACU Select=AT (ACU OPT's menu).

 

for AT ACU.

 

 

 

 

FILE TRANSFER

 

 

Can’t transfer all of a

Check the modem’s flow control

Ensure that the DTE's flow control is the same as the

file or a file aborts in

settings.

modem’s setting (for example XON-XOFF, RTS/CTS).

the middle of transfer

 

 

 

Check whether your

If your communications software supports speed conver-

 

communications package

sion, set modem’s Speed Conver=On (AT*SC1).

 

supports speed conversion.

 

 

 

 

It takes longer than

Confirm which file transfer

Use different protocol, for example, YMODEM,

expected to transfer a

protocol you are using.

Y-GMODEM.

file

 

 

 

 

 

If operating the 326X-SDC modem in SDC mode, and you experience this type of problem...

BER tests do not work

BER tests do not work in SDC

 

 

mode because data is not framed.

 

 

 

 

Modem won’t pass data

Ensure your DTE protocol is

If your protocol is not HDLC/SDLC-like, use direct

 

HDLC/SDLC-like data.

mode.

 

Check for data format mismatch

Set data format option to match the DTE [NRZ

 

between modem and DTE

(AT*DF0) or NRZI (AT*DF1)].

 

(AT*DF).

 

 

Check clocking requirements.

Set modem for internal or external clock as required by

 

 

your application.

 

 

 

Troubleshooting

Troubleshooting Guide 6-7

Page 117
Image 117
Motorola and V.32bis, V.34-SDC, 326X V.34 manual Call Termina Tion