Motorola V.34-SDC, and V.32bis, 326X V.34 manual Fast Call=Off AT*FC0 in it

Models: V.34-SDC and V.32bis 326X V.34

1 240
Download 240 pages 13.02 Kb
Page 118
Image 118

326X Series Modem Troubleshooting Guide (Continued)

Problem

Diagnosis/Test

Possible Solution

 

Check whether modem is set for

If your DTE cannot handle Tx clock stopping, set

 

Flow=Tx Clk (AT*FL5).

Flow=Off (AT*FL0) or use CTS flow control.

 

Check if TpDlyMin=Rx Clk

If your DTE equipment cannot handle Rx clock stopping,

 

(AT*TD1).

set TpDlyMin=Off (AT*TD0) or set TpDlyMin=RxD

 

 

Dly (AT*TD2).

 

If both modems are 326X-SDC,

If the option sets are not the same, select the same option

 

check to ensure option sets are

sets in both modems using Select Options (ATZ) com-

 

the same in both modems.

mand.

 

Check if one of your modems

If the local or remote modem is a 326X-SDC modem, set

 

(local or remote) is a 326X-SDC

Fast Call=Off (AT*FC0) in it.

 

unit.

 

Poor throughput

Check your applications proto-

 

performance

col:

 

 

• If a window size of one is

Increase window size.

 

used (half duplex proto-

 

 

col)...

 

Troubleshooting

• If using Novell IPX...

Check whether TpDlyMin=Off (AT*TD0) or TpD- lyMin=RxD Dly (AT*TD2).

Check if modem is set for Flow=Off (AT*FL0).

If performance is not satisfac- tory, experiment with frame and window sizes.

If link utilization is low

(as shown in the front panel throughput and link utilization status display)...

Ensure burst mode is selected.

If your DTE can handle Rx clock stopping, set TpDlyMin=Rx Clk.

If your DTE can handle Tx clock stopping, set Flow=Tx Clk (AT*FL5). If it does not support Tx clock stopping, use CTS.

The optimum frame size for most applications is between 128 and 1024 bytes.

The optimum window size for most applications is 7 to 4.

Increase the DTE rate.

Poor throughput delay Check the setting of the flow

Use Tx clock or CTS for flow control and Rx clock for

control option.

throughput minimization delay.

 

 

6-8 Troubleshooting Guide

Page 118
Image 118
Motorola V.34-SDC, and V.32bis, 326X V.34 manual Fast Call=Off AT*FC0 in it