S-Register 38—Disconnect Buffer Delay

Stored in Nonvolatile Memory?: Yes

Status-Only?:No

Default:5

Range:

0 to 255 (seconds)

S-Register 38 determines how long the modem processes buffered data when a disconnect is initiated. For S-Register 38 to affect the Delay option (AT*DB), Delay (EC OPT’S menu) must be set to “Buf or S38” or “Buf & S38.”

S-Register 45—Access Security Tone Duration

Stored in Nonvolatile Memory?: Yes

Status-Only?:No

Default:5

Range:

0 to 10 (seconds)

This S-Register specifies the prompt tone duration when the ACCESS SECURITY option Tone=Prompt Only or Prompt/Ack (AT*ZP). This delay is measured from the time that the prompt tone is generated by the answer modem, to the time that the answer modem detects the first digit of the calling modem’s password.

S-Register 46—Access Security Lead Digit Delay Timeout

Stored in Nonvolatile Memory?: Yes

Status-Only?:No

Default:12

Range:

0 to 255 (seconds)

This S-Register specifies the lead digit delay timeout when ACCESS SECURITY Tone (AT*ZP) is enabled.

S-Register 96—Signalling System #5

Stored in Nonvolatile Memory?: Yes

Status-Only?:No

Default:0

Range:0 - 1

This S-Register specifies whether Signalling System #5 is enabled.