EIA-232-D Connections

Interface Characteristics

B

 

The EIA-232-D interface standard specifies all parameters for serial binary data interchange between DTE and DCE devices using unbalanced lines. EIA-232-D transmitter and receiver parameters applicable to the MVME2603/2604 are listed in the following tables.

Table B-2. EIA-232-D Interface Transmitter Characteristics

Parameter

Value

Unit

 

Minimum Maximum

 

 

 

 

 

Output voltage (with load resistance of 3000Ω to

±8.5

 

V

7000Ω)

 

 

 

 

 

 

 

Open circuit output voltage

 

± 12

V

 

 

 

 

Short circuit output current (to ground or any other

 

± 100

mA

interconnection cable conductor)

 

 

 

 

 

 

 

Power-off output resistance

300

 

W

 

 

 

 

Output transition time (for a transition region of

 

2

μs

–3V to +3V and with total load capacitance,

 

 

 

including connection cable, of less than 2500pF)

 

 

 

 

 

 

 

Open circuit slew rate

 

30

V/μs

 

 

 

 

The MVME2603/2604 conforms to EIA-232-D specifications. Note that although the EIA-232-D standard recommends the use of short interconnection cables not more than 50 feet (15 m) in length, longer cables are permissible provided the total load capacitance measured at the interface point and including signal terminator does not exceed 2500pF.

Table B-3. EIA-232-D Interface Receiver Characteristics

Parameter

Value

Unit

Minimum

Maximum

 

 

 

 

 

 

Input signal voltage

 

±25

V

 

 

 

 

Input high threshold voltage

 

2.25

V

 

 

 

 

Input low threshold voltage

0.75

 

V

 

 

 

 

Input hysteresis

1.0

 

V

 

 

 

 

Input impedance (15V < Vin < +15V)

3000

7000

Ω

http://www.motorola.com/computer/literature

B-5

Page 177
Image 177
Motorola MVME2600 manual Interface Characteristics, Table B-2. EIA-232-D Interface Transmitter Characteristics