Installation and Use
Page
Safety Summary
Flammability
CE Notice European Community
Limited and Restricted Rights Legend
Contents
Chapter
Connector Pin Assignments
Appendix a
Appendix D Related Documentation
Page
List of Figures
Page
List of Tables
Xvi
About This Manual
Model Number Description
Overview of Contents
Summary of Changes
Comments and Suggestions
Conventions Used in This Manual
Bold
Hardware Preparation and Installation
Introduction
MVME2603/2604 Base Board Block Diagram
Overview of Startup Procedure
Equipment Required
Startup Overview
Connector Pin Assignments
What you need to do Refer to
Hardware Configuration
Unpacking Instructions
MVME2603/2604 Base Board Preparation
Cache Mode Control J3
Flash Bank Selection J10
Serial Port 4 Receive Clock Configuration J16
MVME2603/2604 Switches, Headers, Connectors, Fuses, LEDs
Serial Port 4 Transmit Clock Configuration J17
Serial Port 4 Transmit Clock Receiver Buffer Control J20
Serial Port 3 Transmit Clock Configuration J18
System Controller Selection J22
MVME712M Transition Module Preparation
Remote Status and Control
MVME712M Transition Module Preparation
OnnectorCLocationsFigure 1-3. MVME712Mand Header
Literature1-16Computer GroupCenter
Serial Port Board Panel Connector Jumper Header
Serial Ports 1-4 DCE/DTE Configuration
Serial Port 4 Clock Configuration
MVME712M Port/Jumper Correspondence
MVME712M Serial Port 1 DCE/DTE Configuration
MVME712M Serial Port 2 DCE/DTE Configuration
MVME712M Serial Port 3 DCE Configuration
MVME712M Serial Port 3 DTE Configuration
MVME712M Serial Port 4 DCE Configuration
10. MVME712M Serial Port 4 DTE Configuration
11. MVME712M P2 Adapter Component Placement
P2 Adapter Preparation
MVME761 Transition Module Preparation
12. MVME761 Connector and Header Locations
Serial Ports 1
Configuration of Serial Ports 3
Port Connector Header J12
Synchronous Board
J2J2
13. MVME761 Serial Ports 1 and 2 DCE Only
14. MVME761 Serial Ports 3 and 4 DCE Configuration
15. MVME761 Serial Ports 3 and 4 DTE Configuration
P2 Adapter Preparation Three-Row
16. MVME761 P2 Adapter Three-Row Component Placement
P2 Adapter Preparation Five-Row
17. MVME761 P2 Adapter Five-Row Component Placement
Hardware Installation
RAM200 Memory Mezzanine Installation
Hardware Preparation and Installation
PMC Module Installation
18. RAM200 Placement on MVME2603/2604
Hardware Preparation and Installation
19. PMC Module Placement on MVME2603/2604
PMC Carrier Board Installation
20. PMC Carrier Board Placement on MVME2603/2604
MVME2603/2604 VME Module Installation
Hardware Installation
MVME712M Transition Module Installation
Hardware Installation
Hardware Preparation and Installation
21. MVME712M/MVME2603/2604 Cable Connections
MVME761 Transition Module Installation
22. MVME761/MVME2603/2604 Cable Connections
System Considerations
MVME2603/2604 VME Module
Hardware Preparation and Installation
System Considerations
Page
Applying Power
Operating Instructions
PPCBug System Startup
Abort Switch S1
Reset Switch S2
Applying Power
Front Panel Indicators DS1 DS6
Memory Maps
Processor Memory Map
Default Processor Memory Map
Processor Default View of the Memory Map
Processor Address Size Definition Start End
PCI Local Bus Memory Map
VMEbus Memory Map
Programming Considerations
VMEbus Master Mapping
PCI Arbitration
PCI Arbitration Assignments
PCI Bus Request PCI Masters
Interrupt Handling
Programming Considerations
MVME2603/MVME2604 Interrupt Architecture
IBC DMA Channel Assignments
Sources of Reset
DMA Channels
Controller DMA Assignment Priority Label
Classes of Reset and Effectiveness
Asic
Endian Issues
Processor/Memory Domain
PCI Domain
PCI and Scsi
VMEbus Domain
Feature Description
Features
MVME2603/2604 Features
ECC Dram
VME I/O
Scsi I/O
General Description
Block Diagram
MVME2603/2604 Block Diagram
Scsi Interface
Scsi Termination
Ethernet Interface
PCI Mezzanine Interface
PMC Connectors
Signaling Voltage
Mezzanine Type
VMEbus Interface
ISA Super I/O Device Isasio
Asynchronous Serial Ports
Parallel Port
PCI-ISA Bridge PIB Controller
Disk Drive Controller
Keyboard and Mouse Interface
Real-Time Clock/NVRAM/Timer Function
Programmable Timers
Interval Timers
Bit Timers
Serial Communications Interface
Z8536 CIO Device
Base Module Feature Register
Base Module Feature Register Offset $0802
SD7 SD6 SD5 SD4 SD3 SD2 SD1 SD0
P2 Signal Multiplexing
P2 Multiplexing Sequence
DCD1
RLB4 DCD4 Idreq ∗ TM4/MID2 DTR1 RI4 DTR2 RI1
DSR1
RI2
Front Panel Indicators DS1 DS6
Fuse Assignments
Polyswitches Resettable Fuses
Power
Fuse Voltage
Speaker Control
PM603/604 Processor
RAM200 Memory Module
Flash Memory
MVME712M Transition Module
MVME761 Transition Module
Serial Interface Modules
SIM Type Identification
Model Module Number Type
Page
Connector Pin Assignments
MVME2603/2604 Connectors
Connector Pin Assignments
Common Connectors
LED Mezzanine Connector J1
LED Mezzanine Connector
PA0 PA1
Debug Connector J2
Debug Connector
GND
PDPAR4 PDPAR5
PDPAR0 PDPAR1
PDPAR2 PDPAR3
PDPAR6 PDPAR7
TT2 TSIZ2
TT0 TSIZ0
TT1 TSIZ1
TT3 TC0
Floppy/LED Connector J4
Floppy/LED Connector
PCI Expansion Connector J5
PCI Expansion Connector
GND Trdy ∗ Irdy ∗
Trst ∗ PMC2P ∗ PMC2GNT ∗ PMC2REQ ∗
Lock ∗ Sdone Devsel ∗
PAR
PAR64
Keyboard and Mouse Connectors J6, J8
Keyboard Connector
Mouse Connector
Dram Mezzanine Connector J7
Dram Mezzanine Connector
Aras ∗ Acas ∗
RDL58 RDL59
RDL6 RDL7 RDL8 RDL9 RDL10 RDL11 RDL12
RDL56 RDL57
RDL60 RDL61
CDL6 CDL7
CDL2 CDL3
CDL4 CDL5
RDU0 RDU1
PCI Mezzanine Card Connectors
PCI Mezzanine Card Connector
J11 J12
J13 J14
PMCIO16 PMCIO17
GND PMCIO12 PMCIO13
PMCIO14 PMCIO15
GND PMCIO18 PMCIO19
VMEbus Connector P1
VMEbus Connector P1
Row Z Row a Row B Row C Row D
VMEbus Connector P2
10. VMEbus Connector P2 MVME712M I/O Mode
MVME712M-Compatible Versions
SDBP0
PMCIO4 GND
PMCIO6 GND
PMCIO8 GND
GND DBP ∗
Scsi Connector
11. Scsi Connector MVME712M
Termpwr GND ATN ∗ BSY ∗ ACK ∗ RST ∗ MSG ∗ SEL ∗ REQ ∗
Serial Ports
12. Serial Connections-MVME712M Ports
Prstb ∗ GND PRD0 PRD1 PRD2 PRD3 PRD4 PRD5 PRD6 PRD7
Parallel Connector
13. Parallel I/O Connector MVME712M
GND Prbsy Prpe Prsel Inprime ∗
Ethernet AUI Connector
14. Ethernet AUI Connector MVME712M
15. VMEbus Connector P2 MVME761 I/O Mode
MVME761-Compatible Versions
PMCIO16
16. Serial Connections-Ports 1 and 2 MVME761
Serial Ports 3
17. Serial Connections-Ports 3 and 4 MVME761
18. Parallel I/O Connector MVME761
Prbsy GND Prsel
GND Prpe PRD0 PRD1 PRD2 PRD3 PRD4 PRD5 PRD6 PRD7
Ethernet 10BaseT/100BaseTX Connector
19. Ethernet 10BaseT/100BaseTX Connector MVME761
Page
PPCBug
Overview
Memory Requirements
PPCBug Implementation
Using the Debugger
Debugger Commands
Debugger Commands
Command Description
Fork
Gevboot
ENV
Forkwr
MAW
Pboot
Reset
MD, MDS
Srom
RUN
SET
SYM
Diagnostic Tests
Diagnostic Test Groups
Test Set Description Applicability
Cnfg and ENV Commands
Cnfg Configure Board Information Block
Configuring the PPCBug Parameters
ENV Set Environment
Remote Start Method Switch G/M/B/N = B?
Wide Scsi 16-bit bus Narrow Scsi 8-bit bus. Default
Nvram Bootlist GEV.fw-boot-path Boot Enable Y/N = N?
Default = $00
Auto Boot Abort Delay = 7?
ROM Boot Direct Ending Address = FFFFFFFC?
Default Starting Address is $00000000
ROM Next Access Length 0 15 = 0?
Configuring the VMEbus Interface
PCI Slave Image 0 Bound Address Register = 00000000?
PCI Slave Image 3 Control = C0400000?
VMEbus Slave Image 1 Base Address Register = 00000000?
VMEbus Slave Image 3 Translation Offset = 00000000?
Specifications
Table A-1. MVME2603/2604 Specifications
Characteristics Specifications
Cooling Requirements
FCC Compliance
Page
Asynchronous Serial Ports
Synchronous Serial Ports
EIA-232-D Connections
Table B-1. EIA-232-D Interconnect Signals
Pin Signal Signal Name and Description Number Mnemonic
BSY
Interface Characteristics
Table B-2. EIA-232-D Interface Transmitter Characteristics
Table B-3. EIA-232-D Interface Receiver Characteristics
Table B-4. MVME761 EIA-530 Interconnect Signals
EIA-530 Connections
EIA-530 Connections
Table B-5. EIA-530 Interface Transmitter Characteristics
Table B-6. EIA-530 Interface Receiver Characteristics
Proper Grounding
Page
CTroubleshooting CPU Boards Solving Startup Problems
Table C-1. Troubleshooting MVME2603/2604 Boards
Troubleshooting CPU Boards Solving Startup Problems
Introduction
Troubleshooting Procedure Complete
Motorola Computer Group Documents
Document Title Publication Number
Manufacturers’ Documents
Document Title and Source Publication Number
MPCFPE/AD
MPC2604GA
CA91C042
Related Specifications
ANSI/IEEE
IEC 821 BUS
MPR-PPC-RPU-02
Isbn
Member countries
TIA/EIA-232
Page
Index
Dram
PCI bus 2-4,2-7,3-3,3-7,3-11,3-17
Romnal Scsi