Status Registers

Inactivity Timer — S58

The S58 register specifies the number of minutes the modem waits before terminating a call when no data is sent or received. This register is active when in error control mode. 0 disables timer. Issue the \Tn command to load inactivity timer, n=0-255 minutes.

Bit

Value

Command

Description

 

 

 

 

7-0

0

\T

Disable

 

1-255

\Tn (n=1-

Timer value in minutes

 

 

255)

 

 

 

 

 

Break Control — S59

The S59 register determines the action taken when a break is encountered. Refer to the “Break Control — \Kn” section on page 6-9 for further information.

Bit

Value

Command

Description

 

 

 

 

2-0

000

\K

Break option 0

 

001

\K1

Break option 1

 

010

\K2

Break option 2

 

011

\K3

Break option 3

 

100

\K4

Break option 4

 

101

\K5

Break option 5

 

 

 

 

7-3

--

--

Reserved

 

 

 

 

Bit Mapped — S60

Bit

Value

Command

Description

 

 

 

 

0

0

%E

Disable auto retrain

 

1

%E1

Enable auto retrain

 

 

 

 

1

0

 

MNP compression disabled

 

1

 

MNP compression enabled

 

 

 

 

2

0

\C

Disable auto-reliable data buffer

 

1

\C1

Buffer data for 4 seconds or 200 characters

 

 

 

 

5-

--

--

Reserved