Test Mode Operation

Exiting RDL/TP the modem responds with a three digit value between 0 and 255 representing the number of errors which occurred during test pattern detection. If errors occur, repeat the test several times to verify the consistency of the problem, then use the analog loopback tests to isolate the problem.

Figure 7-5. Local Modem Initiating Remote Digital Loopback with Test Pattern

Test Pattern — %T

In Test Pattern, transmitted data from the local DTE is blocked and replaced by a V.52 compatible test pattern. When the modem transmits the test pattern, it expects to receive the same pattern.

Bilateral Digital Test Enable / Disable — *DG

Enable or disable bilateral test functions.

Command

Operation

 

 

*DG

Bilateral digital loop disabled

 

 

*DG1

Bilateral digital loop enabled

 

 

V.3600

7-7

Page 117
Image 117
Motorola V.3600 manual Test Pattern %T, Bilateral Digital Test Enable / Disable *DG, Bilateral digital loop enabled