Motorola
3600
Modem User’s Guide
Trademarks
Updates
Copyright
Regulatory Information
FCC Requirements
Model Name V.3600, 115 VAC version only
FCC Part 15 Declaration Of Conformity
FCC Fax Branding Requirements
Shielded Cables
Model Name V.3600, all other versions
Special Requirements For Canada
Industry Canada IC Requirements
Ringer Equivalence Number
Canadian Emission Requirements V.3600, other versions
Page
Contents
Contents
Contents
Test Mode Operation
Protocols
Security
Fax Operation
Status Registers
Contents
25 bis Autodialer
Appendix D. Fault Isolation Procedure
Maintenance
Appendix A. Specifications
Appendix B. Phone Jack Descriptions
Appendix E. Command Index and Defaults
Chapter Introduction
Shelf-Mount Units
Features
Data Mode
Communications Software Class 1 Fax Communications Software
Fax Mode
Software
Internet Browser
Physical
Description
Functional
Rear Panel 115 Vac Model
RM16M Unit
RM16M Version
AC Power Connection
Chapter Installation
Electrical Installation
DC Power Connection
Installation
DTE Connection
Digital Interface Signals
Pin Signal Descriptions
140
Dial Mode Pstn Connection Dial jack
Telephone Line Connection
Leased Line Connection TELSET/LEASED Line Jack
Direct connection to the Pstn is shown in Figure
Leased Line Connection 115 Vac Model
Shelf-Mount RM16M V.3600 Installation
RM16M Connections
Page
Option Selection
Power-Up
Chapter Getting Started
Dialing with a Standard Telephone
Autodialing from a Terminal with the AT Commands
Placing a Call
Autodialing from Front Panel
Answering a Call
Ending a Call
Reasons for Call Termination
Condition
Reasons for Call Termination
Page
Chapter Front Panel Operation
LED Descriptions
LCD Menus
LCD Menu Operation
Main Menu LCD Messages Reg
Main Menu Submenu Submenu Item Option Com Reg
Remote Initiate
Submenu Main Menu Option Com Reg
RATION? OPTIONS?
Lease line only † Dial line only 3600
Modify Change DTE Speed DTE=DCE
Modify Change DTE Dial Method Async
Modify Change DTE RTS/CTS Delay
Password of 0000 disables front panel security 3600
Front Panel Security
Page
Operation Modes
Chapter AT Commands
Command Categories
Online Command Mode
Sending Commands to the Modem
Offline Command Mode
Creating a Command Statement AT
Autobaud Guidelines for Creating Command Statements
Monitor Display
Command Statement Buffer
Repeating a Command a
Backspace Key
Group Commands
Response Commands
Numbered Commands
Negotiation Displays W
Digit / Word Selection
Response Displays Q
Connect Message Codes \V
Call Progress / Connect Speed Messages
Command Code Set Number Operation
Number Code Application *RC
Response Number Codes / Messages
Message Meaning
DTE rate 31200 bps
Connect 300/V42
Connect 300/MNP5
Dial Commands
Dialing D
Insert Long Pause
Tone Dialing T
Pulse Dialing P
Wait for Second Dial Tone W
Switching to Answer Mode after Dialing R
Remaining in Command Mode
Hook Flash
Autodial Number Location *AUn
Wait for 5 Seconds of Silence @
Dialing a Stored Telephone Number Sn
Voice Calls
Manual Answer
Switching from Voice to Data
AT Command Answer a
Autoanswer S0
Distinctive Ring *DR
Caller ID Messages Modem sends this message
Terminal Interface Commands
Data Carrier Detect &C
Data Set Ready &S
Data Terminal Ready &D
Serial Port Ring Indicator Pin 22 \R
Request to Send / Clear to Send &R
DTE Controlled Fallback Rate Pin 23 *FB
General Commands
Changing from Data Mode to Command Mode +++
Local Character Echo E
Fast Disconnect H2, H3
Online Character Echo F
Hanging Up H, H1
Speaker Control M
Speaker Volume L
Eprom Check
Long Space Disconnect Y
Asynchronous / Synchronous Mode Selection &M
Return Online O
Bis Guard Tones &G
Make / Break Dial Pulse Ratio &P
Comman Operation
Asymmetric Bit Rates *AS
Synchronous Transmit Clock Source &X
Rate Selection Thresholds *TH
Modulation *MM
Maximum DCE Speed %B
Minimum DCE Speed %L
Auto Retrain %E
Automatic Rate Adaption %R
Manual Rate Adaption *RR
Product Revision Level %V
Talk / Data *DA
Online Quick Reference $H
Product Serial Number $V
Fast Train *FT
Private Line Operation
Disable AT Command Set *NT
Wire Operation
Dial Line Transmit Level *TDn
Wire Leased Line Operation
Wire Dial-up Operation
Dial Backup
Manual Dial Backup *LD
Dial Backup *DB
Return to Leased Line from Dial Backup *LB
Dial / Leased Line &L
Active Profile
Configuration Commands
Configuration Profiles
Stored Profile
Storing a Configuration &W
Powerup Option Set &Y
Reset to Stored Configuration Z
Load Factory Options &Fn
Storing a Telephone Command Line &Zx=n, *CNx,n, *ND
View Configuration Profiles/Received Signal Options &V
Retaining / Restoring Options *RO
Remote Configuration
Soft Download Password %P1, $Y
Remote Configuration Security
Remote Security Code %P=
Entering Remote Configuration %T=, &T
Enabling/Disabling Remote Configuration *RA
Remote Configuration DTE Speed *RB
Remote Configuration Format *RF
Remote Configuration Saving or Discarding Options *RQ
Page
Chapter Protocols
Ccitt V.42 bis Error Control Protocol
Reliable Mode
Constant Speed Interface
Auto-Reliable Mode
Normal Mode
Data Compression
Flow Control
Direct Mode
Protocol Commands
Serial Port DTE Constant Speed \J
Disconnect Buffer Delay Q%D
Command Operation Disconnect buffer delay disabled
Constant
Command Operation Fast detect data sequence disabled
Optional Detection Phase \M
Operating Mode \N
Fast detect data sequence enabled
LAPM, MNP, or normal try both protocols
Command Operation
Auto-Reliable Fallback Character %An
Fallback to normal if not successful
Enable CTS/RTS bilateral flow control
Serial Port Flow Control \Q
XON/XOFF Pass Through \X
Command Operation Disable data link flow control
Enable data link flow control
Data Link Flow Control \G
Break Control \Kn
Break option
Inactivity Timer \T
Maximum Reliable Block Size \A
42bis Data Compression %C
Transmit Break / Set Break Length \B
Set Auto-Reliable Buffer \C
Page
Test Offline Online
Chapter Test Mode Operation
Test Categories
Terminating a Test in Progress Q&T
Grant remote requested digital loopback
Testing the Local Modem
Local Analog Loopback &T1
Testing the Remote Modem
Local Analog Loopback with Self Test &T8
Local Digital Loopback &T3
Grant/Deny RDL Request &T4, &T5
Remote Digital Loopback &T6
Remote Digital Loopback with Self Test &T7
Bilateral digital loop enabled
Bilateral Digital Test Enable / Disable *DG
Command Operation Bilateral digital loop disabled
Test Pattern %T
LAL enabled pin
Command Operation Ignore pin
RDL enabled pin
DTE Controlled Remote Digital Loopback Pin
Chapter Security
Autocallback Security
Operating with Low Security
Low Security Operation
Operating without Low Security
Remote Operation
LCD Indication of Security
Passwords
Local Operation
Restrictions in Security Operation
Low Security Commands
High Security
Security Levels
Superuser
Enabling High Security $EH=pw
High Security Commands
Default Passwords
Set Security Levels $Ln=m
Setting Passwords $Pn=pw$pw
Disabling High Security $D
Display/Reset Illegal Access Attempt Counters $M, $Mn, $M
Extended Features $W
Display Extended Feature Status $W?
Set User Callback Number $Cn=m
Security Status $E?
Factory Reset $F=pw$pw
Removing a User $Rn
Display User Status $S?
Local Logon Command $n=pw
Local Logoff Command $$
Verify User Information $In, $IBn
Remote Logon Procedure $n=pw
$n=pw
Chapter Fax Operation
Fax Operation
Fax Autoanswer
Fax Defaults
Modem Initialization
Stored Fax Profile
Fax Associated Options
Class 1 Details
Class 1 Commands
Dial Command D
Answer Command a
AT Responses to the ATD Command
On Hook H
Service Class Indication +FCLASS?
Service Class Capabilities +FCLASS=?
Off Hook H1
Fax Transmit and Receive Modes
Transmit Silence +FTS=Time
Receive Silence +FRS=Time
Value Modulation Speed
Facsimile Transmit +FTM=Mod
Facsimile Receive +FRM=Mod
Test Supported Range of Values +FTx=?, +FRx=?
Hdlc Transmit +FTH=Mod
Hdlc Receive +FRH=Mod
Binary File Transfer
Class 1 Result Code +FCERROR
Command Description
Fax Autoanswer +FAA=
Chapter Status Registers
Registers
Changing S-Register Values
Register Operation Sn?, Sn?
Changing Register Values Sn=v, Sn=v
Individual Bit Command Sn . # =v
ATSn.#=v
Escape Character S2
Autoanswer S0
Ring Count S1
End-of-Line Character S3
Lost Carrier Detect Time S10
Pause Interval for Comma S8
Carrier Detect Time S9
Dtmf Tone Duration S11
Escape Sequence Pause S12
S13
Bit Mapped S14
S15
S17
Test Timeout S18
System Tests S16
S19
Bit Mapped S21
Bit Mapped S22
S24
RTS/CTS Delay S26
Bit Mapped S23
DTR State Recognition S25
Bit Mapped S29
Lookback Timer S28
Bit Mapped S27
Bit Mapped S30
S31
Bit Mapped S32
DTR / Dial Backup Number to Dial S35
Remote Configuration Escape Character S41
S33
XON Character from DTE S44
Remote Configuration Guard Time S42
S43
Xoff Character from DTE S45
Flow Control S54
Leased Line Transmit Level S52
Automatic Rate Adaption Threshold S53
Bit Mapped S57
S55
Compression Control S56
Bit Mapped S60
Inactivity Timer S58
Break Control S59
Maximum Transmit Block Size S63
Disconnect Buffer Delay S62
DTE Options S61
Link Speed Status S67
Auto-Reliable Fallback Character S64
S65-66
S68
DCE Independent Speed S69
33,600 bps
Enable V.42 fast detect
Operating Mode S70
Operating Mode Status S71
Lapm or MNP or native auto-reliable
Bit Mapped S72
Password Timeout S73
Callback Delay S74
Callback Retry S75
Lockout Threshold S77
Callback Retry Delay S76
Autocallback Timer S78
Break Length S79
Serial Port or DTE Speed S80
S80 register indicates the serial port speed
Negotiation Status S82
Enable negotiation status
Minimum DCE Speed S81
S83
S89-S90
S85-S87
Modulation Type S88
Current Modulation S91
S92 S94
Settings S95
Asymmetric Settings S96
Bit Mapped S97
Chapter Bis Autodialer
Select Sync Data
Autodialer Command Strings and Parameters
Software Guidelines
Access these formats using
Invalid Responses
Dial Parameters
Dial Parameters
Bis Commands and Responses
Dial Command CRN nn...n
Dial Stored Number CRS a
Program Number Command PRN ann...n
Intermediate Call Progress Response
Request List of Stored Numbers RLN
Disregard Incoming Call DIC
Link Number by Address PRL ab
Connect Incoming Call CIC
Redial Last Number CRR n
Request List of Delayed Numbers RLD
Request List of Linked Numbers RLL
RLD
Modem Options Command PRO xxxyy00
Request List of Version RLV
Invms Invalid command message syntax error Examples PRO011
Save Current Settings PRK
Restore Factory Settings PRP n
Request List of Stored Options RLO xxx yy
Option Definition Settings Default
Options
11-16 3600
3600 11-17
Settings Default
Maintenance
Chapter Maintenance
Fuse Replacement
General
Maintenance
Calling Technical Support
Appendix a Specifications
Modulations
Modem Data Rates
Fax Rates
Fax Modulation
Carrier Detect Level
Testing
RTS/CTS Delay
Telco Connection
Page
TELSET/LEASED Line Pin Functions
Appendix B Phone Jack Descriptions
Dial Pin Functions
Page
Removing the Cover
Appendix C Hardware Options
Jumper Option Selection
Figure C-1. Cover Removal
Figure C-2. Jumper Location for Ground Option
Replacing the Cover
Ground Option Jumper
Telephone Interface
Appendix D Fault Isolation Procedure
Fault Isolation Procedure
Standard Phone
Modem and Telephone Line Check
Part
3600
Page
Appendix E Command Index and Defaults
Command Reg Description
Response displays on
Set H command to V.32 †
Speaker off when carrier is present
Response messages
Restore factory configuration 1 †
Negotiation display enabled
Wait for dial tone, detect busy signal
Appropriate connect codes
39/61 pulse make / break ratio
Dial line †
Asynchronous dial / asynchronous data
CTS forced on
Store current configuration to user option
Grant remote commanded digital
View configuration profiles
Powerup with user option set #1
Disable disconnect buffer delay
Bps max
Disable auto-reliable buffer
Disable automatic rate adaption
Transmit a break signal
Disable slaved DTE/DCE speed
Lapm with MNP and normal fallback
Enables bilateral CTS/RTS flow
When call is answered
Manual dial backup operation
Disable protocol result codes
Switches modem to talk mode †
Disables bilateral digital loop
Originate
Command Reg Description Automode modulation
AT command set enabled
15 4800 bps, 18 9600 bps
High rate selection threshold
10-2BER
Fax Commands
Caller ID Commands
Distinctive Ring Commands
Class 1 Commands Valid in Only Fax Mode
Can be one of the following values 0 or
High Security
Security Commands
Disable security
Reinitialize security
Disable user changes password and callback number
Remote Configuration Commands
Enable remote configuration
Default Reg Function Factory Set
Status Registers
Reg Function Factory Set
10-27 Current modulation
Bis Dialer Commands
Synchronous Description Command
Response Messages
Response Message Meaning
Factory Option Sets
Factory Option Set #1
Factory Option Set #
Factory Option Set #3
Modem Options DCE rate
Factory Option Set #5
Factory Option Set #
Synchronous 2-wire Leased Line Normal Originate AT&F7
Synchronous 2-wire Leased Line Forced Answer AT&F8
Factory Option Set #9
Page
Appendix F Ascii and Ebcdic Characters
Binary Decimal Hexadecimal
Symbol Key
Decimal Hex
Symbol
¢ cent
ACK0
143 144 145
Ascii and Ebcdic Characters
Ascii and Ebcdic Characters
Appendix G Abbreviations and Acronyms
EIA
Abbreviations and Acronyms
PIW
Xmit
Steps For Downloading
Appendix H Flash Upgrade
What You Need
Troubleshooting
Flash Upgrade
Appendix I Country-Specific Parameters
Default Available Command Command Name Option Options
India
Japan
Malaysia
Universal/International
Flash Upgrade
Service and Support
Page
What This Warranty Does Not Cover
Motorola Limited Hardware Warranty
Two Year Limited Hardware Warranty
General Provisions
Warranty-2
Index
Numerals
Index-2
Index-3
Index-4
Index-5
Index-6
Index-7
Index-8
Index-9
Index-10
3600 Index-11
Index-12
Index-13