24xx
| FRU | Action |
|
|
|
2 | Pull Tractor | A failed pull tractor sensor can cause |
| Sensor | Load/Unload to malfunction. |
|
| With the tractor in the push position: |
|
| • Press Load/Unload several times while |
|
| alternately holding down and releasing the |
|
| left pull tractor actuator. The paper should |
|
| not park or load when the pull tractor |
|
| actuator is held down. |
|
| • If the paper does park or load with the pull |
|
| tractor actuator held down, go to “Pull |
|
| Tractor Sensor Service Check” on |
|
| page |
|
|
|
POST Service Check
| FRU | Action |
|
|
|
1 | Cables | A faulty interface cable can cause a POST |
|
| error. Disconnect the interface cable from the |
|
| printer and turn the printer off and then on. |
|
| Check the connections of the power cable to |
|
| the logic board. |
|
| Check the condition and continuity of the |
|
| operator panel cable. |
|
|
|
2 | Code Module | Turn the printer off and then on. If you get the |
|
| same error during |
|
| module on the logic board is correctly installed. |
|
|
|
3 | Logic Board | Replace the logic board if necessary and reset |
|
| “Bidirectional Print Adjustment” on |
|
| page |
|
|
|