24xx

Power Service Check

 

FRU

Action

 

 

 

1

Power Supply

If the carrier does not move to the left after

 

 

turning the printer off and then on, be sure the

 

 

line cord voltage to the power supply is correct

 

 

and the power supply outputs are +40 V dc at

 

 

CN12-1, +40 V dc at CN12-2 and +5 V dc at

 

 

CN12-6.

 

 

If the voltages are incorrect:

 

 

• Check the internal fuse before replacing the

 

 

power supply. Generally if F1 is blown, it is

 

 

due to a short in the printhead; replace the

 

 

printhead and the fuse before powering on

 

 

again.

 

 

• Be sure the power supply cable from the

 

 

power supply to the logic board is not

 

 

damaged and correctly installed.

 

 

 

2

Operator Panel

If there is still a power LED problem, check the

 

Operator Panel

operator panel cable continuity and replace the

 

Cable

cable or the operator panel.

 

 

 

3

Carrier Motor

Disconnect the carrier motor from logic board

 

 

CN2 and turn the printer off and then on. If the

 

 

power LED lights correctly only with the carrier

 

 

motor disconnected, replace the carrier motor.

 

 

 

4

Paper Feed Motor

Disconnect the paper feed motor from logic

 

 

board CN1 and turn the printer off and then on.

 

 

If the power LED lights correctly only with the

 

 

paper feed motor disconnected, replace the

 

 

paper feed motor.

 

 

 

5

Printhead

Disconnect the printhead cable from the logic

 

Printhead Cables

board and turn the printer on. If the power LED

 

 

lights correctly only with the printhead cables

 

 

disconnected from the logic board, there is a

 

 

short in the printhead or printhead cables.

 

 

Disconnect the printhead cable from the logic

 

 

board and be sure none of the leads on the

 

 

cable are shorted to ground.

 

 

 

Diagnostic Information 2-27

Page 45
Image 45
Oki 2400 manual Power Service Check