7.Using the UPS monitoring software and contact signal
7.Using the UPS monitoring software and contact signal
*If you do not use the UPS monitoring software and contact signal, this step is not required.
■UPS monitoring software
“PowerAct Pro (for Windows/Linux)” , “UPS service driver” and “UPS Power Manager (Mac)” UPS monitor- ing software is included with this product. Refer to the table below for details about compatibility. Choose which one to use based on the application. Refer to the table below for details about compatibility. For further details about the software functions, refer to the separate "UPS Monitoring Software Quick Installa- tion Guide."
• UPS monitoring software selection table
Model |
| OS |
| Communication method | UPS monitoring software | Required options | Reference |
|
| (sold separately) | |||||
|
| Windows server2003 |
| Serial | PowerAct Pro (Note 1) | – | ⇒See |
|
|
| UPS service (OS standard) + |
| ⇒See | ||
|
| x64 Edition |
| (RS232C or USB 1.1) | – | ||
|
|
| UPS service driver (included software) | ||||
|
| Windows XP/2000 |
|
|
|
| |
|
|
| Contact signal (Note 2) (Note 4) | UPS service (OS standard) | BUC26 | ⇒See | |
|
| x64 Edition |
| ||||
|
|
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See | |
|
|
|
| ||||
|
|
|
| Serial | PowerAct Pro (Note 1) | – | ⇒See |
|
| Windows server2003 |
| UPS service (OS standard) + |
|
| |
|
|
| (RS232C or USB 1.1) | – | ⇒See | ||
|
| Windows XP/2000 |
| UPS service driver (included software) | |||
|
|
|
|
|
| ||
|
|
|
| Contact signal (Note 2) (Note 4) | UPS service (OS standard) | BUC26 | ⇒See |
BU1002SW |
|
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See | |
Windows NT 4.0 |
| Contact signal (Note 2) (Note 3) | UPS service (OS standard) | BUC26 | ⇒See | ||
BU3002SW |
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See | ||
|
| ||||||
|
|
|
| Serial | PowerAct Pro (Note 1) | – | ⇒See |
|
| Windows Me/98 |
| (RS232C or USB 1.1) | |||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See |
|
|
|
| Serial | PowerAct Pro (Note 1) | – | ⇒See |
|
| Linux (Note 2) |
| (RS232C or USB 1.1) | |||
|
|
|
|
|
| ||
|
|
|
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See |
|
| Mac OS X (10.3、10.4) |
| Serial (USB1.1) | UPS Power Manager | – | ⇒See |
|
| Mac OS X Server (10.3, 10.4) |
| ||||
|
|
|
|
|
|
| |
|
| (Note 5) |
| LAN | Shutdown software for SNMP/web card | SC20G | ⇒See |
Note 1: | The most recent version can be downloaded from our homepage |
| |||||
Note 2: | Files cannot be automatically saved. |
|
|
|
| ||
Note 3: | To automatically stop the UPS, it may be necessary to change the PC’s BIOS settings. |
|
| ||||
| Change the PC’s BIOS settings so that the PC’s power supply is not cut after OS shutdown is performed. |
|
| ||||
Note 4: | The UPS automatically stops once the battery is depleted. |
|
|
| |||
Note 5: | Compatible only with Macintosh computers equipped with PowerPC CPU. |
|
|