Omron BU3002SW UPS functions, Turn ON the power switch while the beep stop/test switch is pressed

Models: BU3002SW BU1002SW

1 93
Download 93 pages 54.62 Kb
Page 52
Image 52
Turn ON the power switch while the beep stop/test switch is pressed.

4. UPS functions

Normal status

 

 

There is AC input

A

Turn ON the power switch while the beep stop/test switch is pressed.

 

Power switch “OFF” (Status No. 2)

B

Turn OFF the power switch.

 

 

A

B

 

 

 

 

C Press and hold the beep stop/test switch (for more than 3 seconds).

Setting mode

 

 

 

 

D Press the beep stop/test switch (for less than 3 seconds).

 

 

 

 

 

 

 

 

 

Cold start

 

 

OFF

Cold start OFF mode (Factory-shipped setting)

 

 

 

C

*1

 

 

 

 

 

 

ON/OFF setting

 

 

D

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

ON

Cold start ON mode

 

 

 

D

 

 

 

 

 

 

 

 

Output voltage

C

*1

200V

Output 200V mode (Factory-shipped setting)

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

C

 

220V

Output 220V mode

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

230V

Output 230V mode

D

 

 

 

 

 

 

 

 

D

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240V

Output 240V mode

 

 

Output voltage

C

*1

 

 

 

 

 

 

 

setting

 

0 minute delay (Factory-shipped setting)

 

 

 

 

C

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2 minute delay

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

0.5 minute delay

 

 

 

 

 

 

 

 

 

D

 

 

 

D

D

 

 

 

1 minute delay

D

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

2 minute delay

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

10 minute delay

 

 

 

Signal input/output

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

test

 

 

BL

Battery low signal output test (Factory-shipped setting)

 

 

 

C

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR

Trouble signal output test

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

BU

Backup signal output test

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

WB

Battery replacement signal output test

 

D

 

 

 

 

 

 

D

 

 

 

 

 

 

 

BS

Backup power supply stop signal output test

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

Remote

Remote ON/OFF signal output test

 

 

*1 Displays the current setting value.