Scan reverse
Using an HD lens adapter made by Angenieux, this unit supports the
2 Turn the JOG dial button to move the arrow (cursor) to the “SCAN REVERSE” item.
3 Press the JOG dial button, and set the desired scan reverse.
Turn the JOG dial button, ON or OFF and press the JOG dial button to enter the selection.
Setting the scan reverse
1 Perform the menu operations (pages 86 to 88), and display the “FRAME MODE” screen of FILM (CAM) MAIN MENU 2.
n< FRAME MODE >
FRAME RATE
FRAME RATE | :24 |
SCAN REVERSE | :OFF |
4 Press the MENU button to exit the menu operations.
The setting menu is cleared, and the displays showing the unit’s current statuses appear at the top and bottom of the viewfinder screen.
Adjusting the audio level
When the AUTO SELECT CH1 and CH2 selector switches are set to AUTO, the audio CH1 and CH2 input levels are adjusted automatically.
Proceed as follows to adjust the audio channel 1 and 2 levels manually.
Manual audio level adjustments
1 Set the AUTO SELECT CH1 and CH2 selector switches to MAN.
2 Adjust the AUDIO LEVEL CH1 and CH2 controls in such a way that, when audio signals are input, the level meter reading will not exceed 0 dBu even under maximum signal input level conditions.
AUDIO LEVEL
CH1 control
AUDIO LEVEL
CH2 control
AUTO SELECT CH1 selector switch
AUTO SELECT CH2 selector switch
Limiter
When the audio levels have been adjusted manually, the limiter circuit is tripped by an excessively high input level. This circuit can be turned ON or OFF on the MIC/AUDIO screen of the VTR menu.
(The factory setting is OFF.)
64 (E)