Setting menu screens VTR MAIN MENU
BATTERY/TAPE screen
Item | Variable | VF | Remarks | |
range | display | |||
|
| |||
|
|
|
| |
BATT NEAR | ON | USER | For setting the warning | |
END ALARM | OFF | ENG | tone heard when the | |
|
|
| battery is near the end of | |
|
|
| its charge to ON or OFF. | |
|
|
|
| |
BATT NEAR | ON | USER | For switching the function | |
END CANCEL | OFF | ENG | which cancels the warning | |
|
|
| tone heard when the | |
|
|
| battery is near the end of | |
|
|
| its charge to ON or OFF | |
|
|
| using the MODE switch. | |
|
|
|
| |
BATT END | ON | USER | For setting the warning | |
ALARM | OFF | ENG | tone heard when the | |
|
|
| battery is at the end of its | |
|
|
| charge to ON or OFF. | |
|
|
|
| |
BATT REMAIN | 100% | USER | For selecting the battery | |
FULL | 70% | ENG | capacity at which “FULL” | |
|
|
| is to appear on the LCD | |
|
|
| display window as the | |
|
|
| remaining battery display | |
|
|
| (for all 7 segments to be | |
|
|
| lit). | |
|
|
|
| |
TAPE NEAR | ON | USER | For setting the warning | |
END ALARM | OFF | ENG | tone heard when the end | |
|
|
| of the tape is near to ON | |
|
|
| or OFF. | |
|
|
|
| |
TAPE NEAR | 3min | USER | For setting the remaining | |
END TIME | 2min | ENG | tape time for which the | |
|
|
| warning tone is to be | |
|
|
| heard when the end of the | |
|
|
| tape is near. | |
|
|
|
| |
TAPE END | ON | USER | For setting the warning | |
ALARM | OFF | ENG | tone heard when the tape | |
|
|
| has reached its end to ON | |
|
|
| or OFF. | |
|
|
|
| |
TAPE REMAIN/$ | 3min/$ | USER | For setting the time for | |
| 5min/$ | ENG | one segment of the | |
|
|
| remaining tape display | |
|
|
| indicated on the LCD | |
|
|
| display window. | |
|
|
| 3min/$ : One segment is | |
|
|
| set to 3 minutes. | |
|
|
| 5min/$ : One segment is | |
|
|
| set to 5 minutes. | |
|
|
|
|
BATTERY SETTING screen
The type of battery to be used is selected and its settings are performed on this screen.
Item | Variable | VF | Remarks | |
range | display | |||
|
| |||
|
|
|
| |
MANUAL | ENG | For setting the | ||
| AUTO |
| and the PACO | |
|
|
| battery. | |
|
|
|
| |
MANUAL | ENG | For setting the | ||
| AUTO |
| battery. | |
|
|
|
| |
MANUAL | ENG | For setting the PACO HP- | ||
| AUTO |
| 30A battery. | |
|
|
|
| |
PRO14 | MANUAL | ENG | For setting the | |
| AUTO |
| Anton/Bauer PRO14 | |
|
|
| battery. | |
|
|
|
| |
TRIM14 | MANUAL | ENG | For setting the | |
| AUTO |
| Anton/Bauer TRIM14 | |
|
|
| battery. | |
|
|
|
| |
TRIM13 | MANUAL | ENG | For setting the | |
| AUTO |
| Anton/Bauer TRIM13 | |
|
|
| battery. | |
|
|
|
| |
DIGITAL14 | MANUAL | ENG | For setting the | |
| AUTO |
| Anton/Bauer digital battery | |
|
|
| (14V). | |
|
|
|
| |
DIGITAL13 | MANUAL | ENG | For setting the | |
| AUTO |
| Anton/Bauer digital battery | |
|
|
| (13V). | |
|
|
|
| |
MANUAL | ENG | For setting the IDX BP- | ||
| AUTO |
| H90 battery. | |
|
|
|
| |
MANUAL | ENG | For setting the IDX BP- | ||
| AUTO |
| H100 battery. | |
|
|
|
| |
MANUAL | ENG | For setting the IDX NP- | ||
| AUTO |
| L40 battery. | |
|
|
|
| |
MANUAL | ENG | For setting the IDX NP- | ||
| AUTO |
| L40D battery. | |
|
|
|
| |
MANUAL | ENG | For setting the Sony BP- | ||
| AUTO |
| L60/90 battery. | |
|
|
|
| |
MANUAL | ENG | For setting the Sony NP- | ||
| AUTO |
| 1B battery. | |
|
|
|
|
1.Either “¢” or “≥” appears in front of each item to indicate whether the item is set to ON or OFF.
¢ : ON
≥ : OFF
2.Each time the JOG dial button is pressed, the setting moves in the following sequence:
ON/OFF setting
7
AUTO/MANUAL setting
AUTO : The NEAR END voltage value preset in each battery is used.
MANUAL : The NEAR END voltage setting for each battery can be changed.
7
NEAR END voltage setting
7
Item movement
The underlining in the variable range column indicates the setting in the preset mode.