Feature Guide References
1.17.10 External Relay Control
Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognises the
input and makes a sensor call.
Value Range
32 ´ n (n=2–255) ms
Maintenance Console Location
3.44 [1-1] Slot—OPB3 Card Property
Programming Manual References
None
Feature Guide References
1.17.9 External Sensor
Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from the sensor
will be ignored.
Value Range
10 ´ n (n=1–255) s
Maintenance Console Location
3.44 [1-1] Slot—OPB3 Card Property
Programming Manual References
None
Feature Guide References
1.17.9 External Sensor
SVM Feature
Specifies whether or not to use the ESVM card for the SVM feature. It is possible to use the ESVM card for
the SVM feature, as an MSG card (OGM feature), or both.
Value Range
Disable, Enable
PC Programming Manual 377
3.44 [1-1] Slot—OPB3 Card Property