3.35 [1-1] Slot—Card Property - T1 type
The properties of the T1 card can be specified.
Line Coding
Selects the line coding type of T1 PCM (Pulse Code Modulation) used.
Value Range
B8ZS, AMI
Maintenance Console Location
3.35 [1-1] Slot—Card Property - T1 type
Programming Manual References
None
Feature Guide References
None
Frame Sequence
Selects the type of frame sequence used for communications.
Value Range
D4, ESF
Maintenance Console Location
3.35 [1-1] Slot—Card Property - T1 type
Programming Manual References
None
Feature Guide References
None

ESF Frame Sequence

Selects the values for C-bit and D-bit. To enable this setting, Frame Sequence on this screen should be
set to ESF.
Value Range
C=A, D=B; C=0, D=0; C=0, D=1; C=1, D=0; C=1, D=1