3.38 [1-1] Slot—Card Property - E1 type
The properties of the E1 card can be specified.
To adjust related settings, click Line Signal Setting, MFC-R2 Setting 1, and MFC-R2 Setting 2.
Line Coding
Selects the line coding type of E1 PCM (Pulse Code Modulation) for the E1 card.
Value Range
HDB3, AMI
Maintenance Console Location
3.38 [1-1] Slot—Card Property - E1 type
Programming Manual References
None
Feature Guide References
None
Frame Sequence
Selects the type of frame sequence for the E1 card.
Value Range
PCM30, PCM30-CRC
Maintenance Console Location
3.38 [1-1] Slot���Card Property - E1 type
Programming Manual References
None
Feature Guide References
None

Frame Option

Selects the value for C-bit and D-bit.
Value Range
C=A, D=B; C=0, D=0; C=0, D=1; C=1, D=0; C=1, D=1
PC Programming Manual 333
3.38 [1-1] Slot—Card Property - E1 type