Programming Manual References
3.28 [1-1] Slot—Port Property - LCO Port
Feature Guide References
None
Low Speed Pulse Dial—Break Width
Specifies the maximum length of the break signal in a low speed pulse dial. Low Speed Pulse Dial—Pulse
% Break on this screen determines the value that can be specified here.
Value Range
4 ´ n (n=6–20) ms
Maintenance Console Location
3.27 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.28 [1-1] Slot—Port Property - LCO Port
Feature Guide References
None
Low Speed Pulse Dial—Make Width
Specifies the minimum length of the make signal in a low speed pulse dial. Low Speed Pulse Dial—Pulse
% Break on this screen determines the value that can be specified here.
Value Range
4 ´ n (n=3–15) ms
Maintenance Console Location
3.27 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.28 [1-1] Slot—Port Property - LCO Port
Feature Guide References
None
High Speed Pulse Dial—Pulse % Break
Specifies the % break for a high speed pulse dial. This is the ratio between the break (on-hook) signal and
make (off-hook) signal in a pulse dial.
PC Programming Manual 235
3.27 [1-1] Slot—Card Property - LCO type