Feature Guide References
1.5.4.4 Dial Type Selection
CPC Signal Detection Time—Outgoing, Incoming
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming trunk calls
before disconnecting the line. When None is selected here, the line will not be disconnected when a CPC
signal is not detected.
Value Range
None, 6.5 ms, 8 ´ n (n=1–112) ms
Maintenance Console Location
3.28 [1-1] Slot—Port Property - LCO Port
Programming Manual References
None
Feature Guide References
1.11.10 Calling Party Control (CPC) Signal Detection
DTMF Width
Selects the length of the DTMF tone sent to the analogue trunk.
Value Range
80 ms, 160 ms
Maintenance Console Location
3.28 [1-1] Slot—Port Property - LCO Port
Programming Manual References
None
Feature Guide References
None
Pulse Speed
Selects the speed at which pulse dials are sent to the analogue trunk.
Value Range
Low, High
PC Programming Manual 247
3.28 [1-1] Slot—Port Property - LCO Port