Programming Manual References
None
Feature Guide References
None
Dial—Analogue CO Inter-digit
Specifies the length of time within which subsequent digits of a telephone number must be sent to an analogue
trunk. If no digit is sent before this time expires, the PBX recognises end of dialling and stops muting the
caller’s voice over the analogue trunk.
Value Range
1–15 s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
None
Feature Guide References
None
Dial—Analogue CO Call Duration Start
Specifies the length of time between the end of dialling and the start of the SMDR timer for outgoing analogue
trunk calls.
Value Range
0–60 s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
None
Feature Guide References
1.26.1.1 Station Message Detail Recording (SMDR)
PC Programming Manual 403