Programming Manual References
None
Feature Guide References
None
Outgoing Call

En-bloc Dialling setting

Selects the call dialling mode.
Value Range
En-bloc: The PBX sends all of the dialled digits at once after the extension user completes dialling. The PBX
recognises the end of dialling when (1) # is dialled, if programmed, (2) a preprogrammed telephone number
is dialled, or (3) the inter-digit timer expires.
Overlap: The PBX sends dialled digits one at a time.
Maintenance Console Location
3.9 [1-1] Slot—Shelf Property - Virtual IP Gateway
Programming Manual References
None
Feature Guide References
1.30.2 Voice over Internet Protocol (VoIP) Network

Overlap—First-digit Timer (T302-1)

Specifies the length of time within which the first digit of a dial number must be dialled after seizing a virtual IP
trunk.
Value Range
5–30 s
Maintenance Console Location
3.9 [1-1] Slot—Shelf Property - Virtual IP Gateway
Programming Manual References
None
Feature Guide References
None
148 PC Programming Manual
3.9 [1-1] Slot—Shelf Property - Virtual IP Gateway