Programming Manual References
None
Feature Guide References
1.14.1.2 Conference
Unattended Conference—Disconnect Timer
Specifies the length of time until an Unattended Conference is disconnected after the parties involved in the
conference receive a warning tone but the conference originator does not return to the conference.
Value Range
0–240 s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
None
Feature Guide References
1.14.1.2 Conference
Miscellaneous
Caller ID—Waiting to receive
Specifies the length of time that the PBX waits to receive Caller ID from an analogue trunk. If the Caller ID is
received through an analogue trunk card on which no Caller ID card is mounted or through a port to which
Caller ID Detection is disabled, this timer is not applicable.
Value Range
0–15 s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
5.3 [3-1-3] Caller ID Modification
8.1 [6-1] System Speed Dial
Feature Guide References
1.18.1 Caller ID
414 PC Programming Manual
4.5 [2-3] Timers & Counters