Value Range
A-bit, B-bit, C-bit, D-bit
Maintenance Console Location
3.39 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
Meter Pulse Detection—Length
Specifies the length that a call charge meter pulse must be for the PBX to recognise it as a call charge meter
pulse.
Value Range
8 ´ n (n=1–80) ms
Maintenance Console Location
3.39 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
DSP Gain Adjustment—DTMF Transmit
Specifies the output power of the DTMF signal sent from the DSP (Digital Signal Processor).
Value Range
-12 dB–3 dB
Maintenance Console Location
3.39 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
PC Programming Manual 347
3.39 [1-1] Slot—Card Property - E1 type—Line Signal Setting