Feature Guide References
None
ISDN Extension—T309
Specifies the length of time that the PBX tries to disconnect the data link, before disconnecting the call.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.30 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN Extension—T310
Specifies the maximum time that the PBX waits for a reply after receiving the Incoming Call Proceeding
message.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.30 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN Extension—T312
Specifies the maximum time that the PBX waits for a reply after sending the SETUP (call setting) message to
ISDN.
Value Range
0–600 ´ 100 ms
PC Programming Manual 263
3.30 [1-1] Slot—Card Property - BRI type/PRI type