Programming Manual References
None
Feature Guide References
None
Option 6 (CTI)

1st Party CTI—System status retry interval timer

Specifies the length of time until the alive check is retried when no response is received, for First Party Call
Control CTI.
Value Range
0–60 s
Maintenance Console Location
4.18 [2-9] System Options
Programming Manual References
None
Feature Guide References
1.32.1 Computer Telephony Integration (CTI)

1st Party CTI—System status retry counter

Specifies the number of times that the alive check is repeated for First Party Call Control CTI. When the alive
check has been attempted the programmed number times without success, the PBX assumes that the logical
connection with the CTI application software has been lost.
Value Range
0–10
Maintenance Console Location
4.18 [2-9] System Options
Programming Manual References
None
Feature Guide References
1.32.1 Computer Telephony Integration (CTI)
508 PC Programming Manual
4.18 [2-9] System Options