Parameters for the "Network setup" Items Depending on the Connection Type

Item

Connection type

Description of the parameter

 

IP address

Connection type 1

Enter “xxx.yyy.zzz.nnn” for the IP address (where “xxx.yyy.zzz”

 

 

should be the same numbers assigned to the PC, and “nnn” should

 

 

be a number from 2 to 254 except the same IP address already

 

 

assigned to the PC and any other cameras).

 

 

 

 

 

Connection type 2

Set the IP address designated by your network administrator.

 

 

However, the setting is not required if the DHCP is used in an

 

 

intranet.

 

 

 

 

 

Connection type 3*1

Set the IP address designated by your Internet service provider.

 

 

Connection type 4*2

If the broadband router uses the DHCP: No setting required

 

 

If the broadband router does not use the DHCP: Assignment of a

 

 

private IP address is required. However, the IP addresses already

 

 

assigned to the PC and other cameras are not available.

 

 

For further information, refer to the operating instructions of the

 

 

broadband router.

 

 

 

 

Netmask

Connection type 1

Use the default setting "255.255.255.0" for the subnet mask.

 

 

 

 

 

Connection type 2

Set the subnet mask designated by your network administrator.

 

 

However, the setting is not required if the DHCP is used in an

 

 

intranet.

 

 

 

 

 

Connection type 3

Set the subnet mask designated by your Internet service provider.

 

 

 

 

 

Connection type 4

If the broadband router uses the DHCP: No setting required

 

 

If the broadband router does not use the DHCP: Setting of the sub-

 

 

net mask is required.

 

 

For further information, refer to the operating instructions of the

 

 

broadband router.

 

 

 

 

Default gateway

Connection type 1

If the IP address is set for “xxx.yyy.zzz.nnn”, enter “xxx.yyy.zzz.1”

 

 

for the default gateway.

 

 

 

 

 

Connection type 2

Set the IP address of the default gateway designated by your net-

 

 

work administrator.

 

 

However, the setting is not required if the DHCP is used in an

 

 

intranet.

 

 

 

 

 

Connection type 3

Set the default gateway designated by your Internet service

 

 

provider.

 

 

 

 

 

Connection type 4

If the broadband router uses the DHCP: No setting required

 

 

If the broadband router does not use the DHCP: Assignment of an

 

 

IP address to the router is required.

 

 

For further information, refer to the operating instructions of the

 

 

broadband router.

 

 

 

 

*1 If the camera is accessed via the Internet, set the global IP address.

*2 If the camera is accessed via the Internet, assign the global IP address to the broadband router, and set the address translation function to use. (Refer to page 26.)

27

Page 27
Image 27