9401/9402 System Administrator's Guide

Bar Code Field

Message Structure

Syntax

B1,B2,B3,B4,B5,B6,B7,B8,B9,B10,B11,B12 p

B1.B

Indicates record is a bar code field.

B2.field #

Unique number from 1-14to identify this field.

B3.# of char

Maximum number of characters. Range 1-30, except as

 

specified for UPC and EAN codes.

B4.Fix/Var

Fixed or variable length field. Options:

FFixed length

VVariable length field.

B5.row

Distance from bottom of print area to lower left corner of

 

field. (The bottom exits the printer first.) Ranges:

 

English

0

- 600

 

Metric

0

- 1525

 

Dots

0

- 1152

B6.column Distance to lower-left corner of field from left edge of print area. Ranges:

 

English

0 - 200

 

 

Metric

0 - 559

 

 

Dots

0 - 384

 

B7. font

Bar code.

 

 

 

1

UPC-A

6

EAN-8

 

2

UPC-E

7

EAN-13

 

3

I 2 of 5

8

Code 128

 

4

Code 39 (no check digit)

 

B8.density Bar code density. See chart in Quick References.

11-8