2. Designing a Format

10.Write the density selector for your bar code in box B8. Refer to the following tables for the appropriate density selector for your specific bar code.

Barcode

Density

Density

Narrow

Narrow

Data

Appearance

Char

 

 

Type

 

Selector

(% or cpi)

Element

to Wide

Length

Codes

Set

 

 

 

 

 

 

(dots/mils)

Ratio

 

Available

 

 

 

UPCA

2

80%

2/10.4

N/A

11 or 12

1,5,6

0 to 9

 

 

 

 

4

120%

3/15.6

 

 

7 or 8

 

 

 

UPCE

2

80%

2/10.4

N/A

6 or 7

1,5,6

0 to 9

 

 

 

 

4

120%

3/15.6

 

 

7 or 8

 

 

 

EAN8

 

2

80%

2/10.4

N/A

7 or 8

1,5,6

0 to 9

 

 

 

 

4

120%

3/15.6

 

 

7 or 8

 

 

 

EAN13

2

80%

2/10.4

N/A

12 or 13

1,5,6

0 to 9

 

 

 

 

4

120%

3/15.6

 

 

7 or 8

 

 

 

Interleaved

1

1.0

21/109.9

1:3.0

0 to

8

0 to 9

 

 

2 of 5

 

2

2.0

12/62.8

1:2.5

302

 

 

 

 

 

 

 

 

 

 

 

 

3

3.0

7/36.6

1:3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

4.0

6/31.4

1:2.5

 

 

 

 

Designing

 

 

8

8.4

3/15.7

1:2.3

 

 

 

 

 

 

5

5.3

4/20.9

1:3.0

 

 

 

 

 

 

 

6

6.0

4/20.9

1:2.5

 

 

 

 

 

 

 

7

6.9

3/15.6

1:3.0

 

 

 

 

 

 

 

9

9.2

3/15.7

1:2.0

 

 

 

 

a

 

 

 

 

 

 

Format

 

 

12

12.0

2/10.4

1:2.5

 

 

 

 

 

 

10

10.7

2/10.4

1:3.0

 

 

 

 

 

 

 

11

10.7

2/10.4

1:3.0

 

 

 

 

 

 

 

13

13.7

2/10.4

1:2.0

 

 

 

 

 

Code 39

3

3.3

4/20.9

1:2.5

0 to

8

SPACE

 

 

 

 

4

4.0

3/15.6

1:3.0

303

 

$%*+-./

 

 

 

 

 

 

 

 

 

 

6

6.0

2/10.4

1:3.0

 

 

0 to 9

 

 

 

 

7

6.6

2/10.4

1:2.5

 

 

A to Z

 

 

Code 128

4

4.3/8.7

4/20.8

 

0 to

8

00H to

 

 

 

 

 

 

 

 

302

 

7FH1

 

 

 

 

6

5.8/11.7

3/15.6

 

 

 

 

 

 

 

 

8

8.7/17.5

2/10.4

 

 

 

 

 

 

Default values are shown in bold.

 

 

 

 

 

 

(1)

201 - Function Code 1

 

202 - Function Code 2

 

 

 

 

 

 

 

 

 

203 - Function Code 3

 

204 - Function Code 4

 

 

 

(2)Actual maximum number of characters is limited by the supply size and density combination which enable the bar code to be totally imaged on the tag or label.

2-31

Page 49
Image 49
Paxar 9401 manual Barcode Density Narrow Data Appearance Char Type