9401/9402 System Administrator's Guide
Option #20 Defines the operator
| prompt. Can be used | |
| with any option. | |
Syntax | R,20,"prompt in | |
| quotes" p |
|
| ∙ Do not use on fields | |
| filled entirely by fixed | |
| characters or copied | |
| data. |
|
| ∙ The prompt should be 15 characters or less, | |
| enclosed in quotation marks. | |
| ∙ Do not use this option with the Option 5 "N" | |
| listing. |
|
Example | R,20,"Enter Part #:" p | |
| The printer will display "Enter Part #:" for the | |
| operator to enter data in this field. | |
Option #30 Pad data to left or right with | ||
| specified character. Can be used | |
| with any option except Option 42. | |
Syntax | R,30,L/R,"character" p | |
| L/R | L = Pad field on left side |
R = Pad field on right side.
"character" Pad character (must be printable). Character must be enclosed in quotation marks.
NOTE: Do not use on fixed length fields.
Example R,30,L,"X" p
If a variable length field is not completely filled with batch data, this option fills in the remaining positions in the field with the character X.