Connecting the Open Collector Output – F3 (TTL)

F3 is a TTL open collector output. This output provides a path to ground to control the low voltage trigger input on many devices. It can control higher voltage control inputs via isolation relays. Refer to Figure 27 for wiring details.

Do not exceed the voltage and current ratings for the TTL output.

An external pull-up resistor is usually necessary. The formula for calculating the resistor value is given in Figure 26.

12-PIN PLUG-IN CONNECTOR

FROM VIDEO OUTPUT

LOOPED TO MONITOR

+VDC

R= +VDC 25 mA

R

INPUT

DEVICE EXAMPLE: VIDEO PRINTER

+VDC = VOLTAGE OF THE EXTERNAL POWER SOURCE.

NOTE: +VDC SHOULD BE 5V OR GREATER, BUT NOT EXCEED 15V OR TE MAXIMUM RATED OUTPUT VOLTAGE FOR THE DEVICE INPUT. +VDC CAN ONLY BE DC.

Figure 27. Wiring the F3 (TTL) Output

34