96 X 16 SYSTEM SETTINGS

When you connect two CM6800E-48X8 units together in a 96 x 16 system, you must access the System programming screen and change the setting to 96 x 16. Refer to the Programming section for instructions.

KBD960/KBR960 KEYBOARD

Configure the KBD960/KBR960 settings.

1.Set DIP switch 2 to the ON position.

2.Enter Setup Mode. Set the local address (1-8). (Note: the baud rate is set by default to 19200.) Each M device connected to the CM6800E must have a unique local address. Refer to the KBD960/KBR960 Keyboard Installation/Operation Manual for detailed setup instructions.

3.Return DIP switch 2 to the OFF position.

4.Press the EXIT icon on the keyboard LCD screen.

GENEX MULTIPLEXER

Access the Camera programming screen and specify MUX control for all cameras connected to the CM6800E through the Genex Multi- plexer.

Access the CM6800E Camera programming screen to configure the following camera control options for each camera connected to the CM6800E through the Genex Multiplexer:

CONTROL: MUX

PORT ADDRESS: assign the appropriate address. The port address must match the “Unit ID” assigned through the Genex programming screens.

You must also configure the Genex Multiplexer. Refer to the MX4000 Genex Series Simplex and Duplex Multiplexers Installation/ Operation Manual for instructions on accessing the Advanced System Setup programming screen. Select the following options:

SPOT MONITOR DISPLAY: TRACK MAIN

UNIT ID (must match the port address assigned through the CM6800E)

COMM. TYPE: SLAVE (each multiplexer connected to the CM6800E must be in slave mode)