CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS

The CM6800E Matrix Switcher/Controller provides eight communication ports on the rear panel for connecting peripheral components. Instructions are provided in this section for the most commonly used connections.

NOTE: Connection instructions for other peripheral devices, such as the CM9760-MDA or CM9760-CDU-T, are provided as Pelco Technical Tips. Connection instructions for compatible products, such as PelcoNet transmission systems and the VMX300 are provided in the appropriate product installation manual.

Figure 12. Communication Port Inputs

Table B. Communication Port Devices and Wiring

Port

Input Type

Wiring

Pin-Outs

Default Device

Programmable to Other Device(s)

 

 

 

 

 

 

 

1

DB9 or RJ-45

RS-232

2

Rx

PC Setup – CM6800MGR

ASCII device

 

 

 

3

Tx

program

 

 

 

 

5

Ground

 

 

2

RJ-45

RS-232

1

Rx

CM6800E-48X8 for a “bay-to-bay”

ASCII device (only when used in

 

 

 

5

Ground

expansion to a 96x16 system

a 48 x 8 configuration)

 

 

 

8

Tx

 

 

3

RJ-45

RS-485

1

Rx+

M devices — ALM2064,

No

 

 

 

2

Rx-

REL2064, KBD960

 

 

 

 

5

Ground

 

 

 

 

 

7

Tx-

 

 

 

 

 

8

Tx+

 

 

4

RJ-45

RS-485

1

Rx+

Genex multiplexer

CM9760-MDA, ASCII

 

 

 

2

Rx-

 

 

 

 

 

5

Ground

 

 

 

 

 

7

Tx-

 

 

 

 

 

8

Tx+

 

 

5 & 6

RJ-45

RS-485 plus power

1

Rx+

Keyboard (direct powered) –

No

 

 

 

2

Rx-

KBD100, KBD200A, & KBD300A

 

 

 

 

3

KBD power (12V)

 

 

 

 

 

4

KBD Ground

 

 

 

 

 

5

Ground

 

 

 

 

 

7

Tx-

 

 

 

 

 

8

Tx+

 

 

(continued on next page)