AUXILIARY OUTPUTS

The three local auxiliary (AUX) outputs on the rear panel of the CM6800E can be operated manually from a system keyboard or automati- cally in response to an alarm.

PELCO SWITCHER

 

SET AUXILIARY MENU

 

 

MODEL CM6800E

 

 

 

 

 

MAIN MENU

AUX

MODE

MON

DWL

1

CAMERA

1

ALM

01

10

2

LOGICAL CAMERA

2

LAT

02

43

3

MONITOR

3

MOM

03

20

4

ACCESS

 

 

 

 

5

TIME & DATE

 

RETURN

 

6

PORT

 

 

7PRIORITY

8SEQUENCE

9MACRO

10ALARM CONTACTS

11EVENT TIMER

12SET AUXILIARY

13SET PASSWORD

14SYSTEM

15ABOUT CM6800E

ENGLISH

RETURN

Figure 38. Program Auxiliary Outputs

Latching or Momentary Operation

In the MODE field for each auxiliary, select either LAT or MOM.

Alarm-based Operation

1.In the MODE field for each auxiliary, select ALM.

2.In the MON field, select the monitor the auxiliary will follow.

3.In the DWL field, enter the number of seconds the auxiliary will remain active after there is no longer an alarm displayed on a system monitor. The alarm is displayed on a monitor until

the alarm is acknowledged manually (if MANUAL is selected in the alarm contact ACK TYPE field),

the alarm contact times out (if AUTO is selected in the alarm contact ACK TYPE field).

Refer to the ACK TYPE description in Program an Internal or External Alarm Contact.